OWNERS MANUAL
1
24 lItrE
INSTRUCTIONS
Question and Answer IconNeed help?

Do you have a question about the RIDGE RYDER RR0056 and is the answer not in the manual?

Summary

General Safety

Electrical Devices Are Not Toys

Warning about appliance use by children and persons with reduced capabilities.

Safety When Operating The Appliance

Guidelines for safe operation, including power cords, heat, liquids, and storage.

Performance & Function

Assembly And Parts

Operating Instructions

Adjusting To Heat Or Cool

Steps to select desired temperature using up/down buttons and understand display feedback.

Turn Off

Instructions on how to power off the unit and note about fan operation after shutdown.

Hints & Tips

Advice on placement, environment, pre-cooling, food cooling, and medicine storage.

Maintenance And Troubleshooting

Cleaning

Procedure for cleaning the appliance using warm soapy water, avoiding water entry into vents.

Disposal

Guidance on disposing of packaging and the appliance itself according to regulations.

Trouble Shooting

Common faults, possible causes, and suggested solutions for appliance malfunction.

Specifications

Warranty

Warranty Claims

Steps to claim warranty, required documentation, and exclusions for product misuse.

Consumer Rights

Explanation of consumer rights under Australian Consumer Law regarding replacements or refunds.

Overview

This document describes the Ridge Ryder 24 Litre Thermo Cooler, an appliance designed for mobile use, capable of cooling and warming.

Function Description

The Ridge Ryder thermo cooler functions as a portable cooling and warming device. It is not intended to be used as a fridge/freezer. It can cool items down to a maximum of 25°C below the ambient temperature and warm them up to a maximum of 65°C. The actual performance may vary based on conditions such as voltage input, thermal load, ventilation, how often the cabinet is opened and closed, and the temperature of the goods inside. The minimum temperature achievable is dependent on the surrounding ambient/external temperature. For example, if the outside temperature is 30°C, the cooler's minimum temperature will be approximately 5°C. The thermocooler features an automatic voltage change-over function, prioritizing 240V power over 12V power. If 240V power is unavailable, it automatically selects 12V power.

Important Technical Specifications

  • Model: RR0056 Thermo-Cooler 24L
  • Capacity - Gross: 24 Litres
  • Rated Voltage:
    • Input DC (12V):
      • Cool: 70W ± 10%
      • Heat: 60W ± 10%
    • Input AC (220-240V, 50-60Hz):
      • Cool: 55W ± 10%
      • Heat: 63W ± 10%
  • Climate Category: T

Usage Features

The thermo cooler is designed for ease of use with a digital control panel.

  • Power Connection: The device can be connected to either a 12V DC or 240V AC power source using the supplied cables.
  • Power On/Off: The unit is powered on by pressing the power button on the display. To turn off, press the power button again. Note that fans may continue to run for up to 30 seconds after turning off.
  • Temperature Adjustment:
    • Press the "temp set" button; the display will flash.
    • Use the up/down buttons to select the desired temperature for either cooling or warming.
    • Once the desired temperature is set, the display will revert to showing the current cabinet temperature.
    • A green light on the display indicates cooling mode, and a red light indicates warming mode.
    • A fan sound will be audible when heat or cool mode is activated.
  • Placement: Place the appliance on stable ground when in use.
  • Cooling Efficiency:
    • Ensure the appliance is located in a shady spot for effective cooling.
    • For optimal use, it is recommended to cool the unit overnight with nothing inside.
    • Allow warm foods to cool down first before placing them in the appliance.
  • Medicine Storage: If storing medicine, verify that the cooling capacity of the device meets the medication's requirements.
  • Safety:
    • Always ensure power cords are serviceable and dry before use.
    • Do not place the appliance near open flames or other heat sources (heaters, strong solar rays, gas ovens, etc.).
    • Do not fill the interior with liquids or ice.
    • Protect the appliance and cables from heat and moisture.
    • Ensure hands are dry before handling the plug or switching on the appliance.
    • Do not store explosive substances like aerosol cans with flammable propellants inside.
    • The appliance is suitable for camping use but not for household or similar applications like staff kitchens, farmhouses, hotels, motels, bed and breakfasts, catering, or similar non-retail applications.
    • The appliance should not be exposed to rain.

Maintenance Features

  • Cleaning:
    • Always disconnect the power cable from the power source before cleaning.
    • Use warm soapy water and mild detergents to wipe down all internal and external surfaces.
    • Take care to prevent water from entering any vents or electrical connections.
    • Do NOT submerge or rinse the appliance under water, in a bowl, or sink.
    • Do NOT use abrasive cleaners or bleach.
  • Troubleshooting: The manual provides a troubleshooting guide for common issues:
    • Appliance not functioning/internal fan not heard: Check if the display is on, check the input power source, inspect cable connections, check the fuse in the cigarette lighter tip (for 12V DC), ensure the ignition switch is on (for 12V DC in vehicles), check the 12V socket fuse, try an alternative 12V power supply, ensure the 240V lead is connected correctly, and confirm power is turned on.
    • Appliance not operating/display illuminated/internal fan heard: Check if the ambient temperature is above 35°C, move to a cooler location, ensure vents are not blocked, and remove some produce to reduce thermal mass.
    • Appliance not operating/internal fan not heard (Thermo-Electric system defective): Contact Customer Service.
    • Appliance not reaching set temperature: Move the appliance to a cooler area or change the temperature setting, as the unit is only capable of cooling 25°C below ambient or warming up to a max of 65°C.
  • Disposal: Dispose of packaging materials in appropriate recycling bins. For appliance disposal, contact your local recycling center or specialist dealer for details on applicable regulations.

RIDGE RYDER RR0056 Specifications

General IconGeneral
BrandRIDGE RYDER
ModelRR0056
CategoryAccessories
LanguageEnglish