Do you have a question about the Riello UPS Netman208 and is the answer not in the manual?
Type | Network Management Card |
---|---|
Compatibility | Riello UPS |
Form Factor | Plug-in card |
Category | PCI Card |
Model | Netman208 |
Manufacturer | Riello |
Interface | Ethernet |
Network Interface | Ethernet |
Management Protocols | HTTP, SNMP, Telnet, SSH |
Management | Remote Management |
Function | Remote UPS monitoring and management |
Explains symbols like Warning and Information used in the manual.
Contains safety precautions that must be followed scrupulously.
Discusses the company's commitment to environmental aspects and product design.
Provides instructions for the proper disposal of the device's toxic internal materials.
General overview of the Netman 208 accessory and its capabilities.
Lists the items included in the Netman 208 package.
Details of the RJ45 network port and its status LEDs.
Functionality of the reset button for reboot and recovery mode.
Explains the meaning of different status LED colors and patterns.
Information on available user accounts (admin, power) and their privileges.
Using SSH client for remote configuration.
Using HTTP for device configuration and monitoring via web browser.
Explanation of SNMP protocol and Netman 208 as an SNMP agent.
Monitoring device status via Modbus TCP/IP protocol.
Monitoring device status using the BACnet/IP protocol.
Using FTP for file exchange and configuration.
Configuring email notifications for alarm conditions.
Recording and downloading device events.
Recording and downloading UPS main data.
General configuration procedures via HTTP web interface.
Accessing the web configuration with admin or power user accounts.
Setting up general device parameters like PRTK code and name.
Configuring settings to inhibit remote command execution.
Enabling and configuring the data logging service.
Configuring network parameters like hostname, IP, gateway, and DNS.
Firewall configuration to allow or block incoming traffic.
Explanation of basic firewall logic, rules, and testing procedures.
Configuring MAC addresses for Wake-on-LAN operations.
SNMP configuration settings and modes.
Configuring the syslog service for sending events via UDP.
Configuring NTP synchronization for correct date and time.
Configuring email notifications for alarms and reports.
Configuring SMS notifications for alarm conditions via GSM modem.
Configuring the SSH client service for remote hosts.
Configuring VMware ESXi shutdown service.
Configuring Nutanix shutdown service.
Enabling and configuring ESXi autostart functionality for VMs.
Configuring Netman 208 for host shutdown via Syneto.
Enabling automatic checks for firmware and application updates.
Procedure to upgrade the Netman 208 firmware.
Resetting the device to its default configuration using a security code.
Process for changing local passwords for admin and power users.
Configuring login settings, including auto-logout and authentication methods.
Executing a test of the device's batteries.
Executing a shutdown and restore sequence for the device.
Accessing submenus for IP configuration and reboot via SSH setup.
Using advanced commands in expert mode for configuration.
Method for configuring multiple devices with similar parameters using FTP.
Downloading and sending service logs for troubleshooting.
Detailed configuration of SNMP using wizard or editing snmp.conf.
Overview of Modbus TCP/IP protocol, functions, and accessible tables.
Mapping of BACnet/IP objects to their descriptions and units.
List of event codes and their corresponding descriptions.
Pinout for RJ-12 serial port and modem connections.
Network cable requirements and connections.
Environmental conditions for operation and storage.
Legal information, warranty, and open-source components.