EasyManua.ls Logo

Rievtech ELC Series - Page 345

Rievtech ELC Series
355 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
Programmable Relay User Manual for ELC, EXM and PR Series 345 2020 v6.0 © Rievtech Co.,
Ltd. www.rievtech.com
CPU
14
I/O
Expandable
PR-14
Model: PR-14AC-R
AC
Model: PR-14DC-DA-R
DC
Item PR-14AC-R PR-14DC-DA-R
Nominal voltage AC 110V-240V
AC 85 - 265V
47-63Hz
-
-
1780VAC
49 mA (85VAC)
37 mA (265VAC)
Yes
DC 12-24V
DC 10.8-28.8V
-
Typ 5 ms
Max 0.25A
-
3.5W (10.8V DC)
4W (28.8V DC)
Power
Operating limits
The main
frequency range
Immunity from micro
power
Max startup current
Isolation voltage
Protection against
polarity inversions
Input No 10 (I1-IA)
10 (I1-IA)
-
AC 110-240V
AC 0-40V <0.03mA
AC 79-240V >0.06mA
-
-
-
-
-
6 (I1-I6) (0..10V DC)
DC 0-28.8V
Typ 4 Hz
Contact or 3-wire PNP
Resistive
0 to 1 120VACTyp. 50 ms
240VACTyp. 30 ms
1 to 0 120VACTyp. 90 ms
240VACTyp.100 ms
Inputs
Inputs used as digital
Inputs used as analog
Digital input
Analogue input
Input voltage
Input signal 0
Input signal 1
Response time
Sensor type
Input type
Isolation between power
supply and inputs
Isolation between inputs
Measurement range
Input impedance
Input voltage
Resolution
Cable length
Accuracy at 25
Accuracy at 55
Isolation between analog
inputs and power supply
Yes
-
-
-
-
-
-
-
DC 0-10V
28.8V DC max
10bit 0.01V
?(Max 0.02)V
?(Max 0.04)V
-
10 m max shielded & twisted
Protection against
polarity inversions
Maximum counting
frequency
Item PR-14AC-R PR-14DC-DA-R
Output No 4 (Q1-Q4)
Relay output
Resistive load 10A/Inductive load 2A
AC 250V
DC 110V
1250VA
300W
105 Operations at Rated Resistive Load
Against short-circuits: None
Against overvoltages and overloads: None
107 Operations at No Load condition
Outputs
Output type
Continuous current
Max breaking voltage
Max allowable
power force
Electrical durability
expectancy
Built-in protections
Response time
OperateTime: 15 ms max
ReleaseTime: 10 ms max
10Hz
2Hz
0.5Hz
Switch
frequency
Mechanism
Resistor/light load
Sensitive load
Item PR-14
Memory 512 Functional Blocks / 5K Steps
10 years
10 years
Backup at 25 : 20 days, RTC accuracy: MAX ?S/day
0.6ms - 8.0ms
16 modules (PR-E-16)
1 RS232 port & 2 RS485 port (1 built-in)
Modbus RTU/ASCII Master or Slave
General data
Data Retentivity
Program
Backup
RTC
Cycle time
Expansion
Communication
OperationTemp -20 .. +55
-40 .. +70
IP20
95*90*55 (Unit, mm6DIN
35mm-DIN rail or screw for installation
Approx. 400g
StorageTemp
Protection
Dimensions
Installation
Weight
(I1-I6) <0.1mA / (I7-IA) <1mA @ < 5V DC
(I1-I6) >0.3mA / (I7-IA) >1.7mA @ > 8V DC
(I1-I6) 0.4mA / (I7-IA) 2.3mA @ 10.8V DC
(I1-I6) 0.5mA / (I7-IA) 2.6mA @ 12.0V DC
(I1-I6) 1.2mA / (I7-IA) 5.2mA @ 24V DC
(I1-I6) 1.5mA / (I7-IA) 6.3mA @ 28.8V DC
(I1-I6): 0 to 1Typ. 1.5 ms
1 to 0Typ. 1.5 ms
(I7-IA): 0 to 1Typ. <1 ms
1 to 0Typ. <1 ms
I1-I6 4 Hz
I7-IA 60 kHz
I/O circuit diagrams
[Digital Input - Power DC]
(1)
DC 12-24V
+
-
[Digital Input - PowerAC]
AC 110-240V
L N I1 I2 I3 I4
(1)
DC 12-24V
max 10m
2k2/0.5W
10k max
Ca/Ta
[DC analog inputs 0-10V - Power DC ]
(1)
+
-
+
-
[Relay Outputs] [RS485 Connection]
L/+
(1)
(2)
(2)
Q2
A+ B-
Built-in port RS485
Cable length max 1200m Total 20 stantions
Q1
N/-
(1) - Fuse, circuit-breaker or circuit protector
(2) - Inductive load;
A+ B-
A+ B- A+ B-
B-
A+
B-
A+
A+ B-

Related product manuals