Introduction to the MiniFlex 600 as a successor to previous models, highlighting improved performance and compact size.
Explanation of the optical geometry of the MiniFlex 600 utilizing the scintillation counter (SC) for X-ray diffraction.
Lists the standard components included in the MiniFlex 600 system for basic operation.
Visual identification and naming of the main unit's components and block diagram.
Detailed inventory of all items shipped with the MiniFlex 600, categorized by type.
Specifies the necessary conditions for the installation room, including space and environmental factors.
Details on power requirements, grounding, and cooling water specifications for system installation.
Instructions for unpacking the main unit and component parts and verifying against the shipped items list.
Step-by-step guide for installing the Scintillation Counter (SC) and the optional D/teX Ultra detector.
Procedures for installing the X-ray tube and connecting the cooling water hoses.
Instructions for installing various optical components like slits, beam stops, and knife edges.
Guides for connecting power and computer cables and installing the system software.
Details on types of Soller slits and how to confirm their installation.
Procedure for aligning optics when using the Scintillation Counter (SC).
Steps for adjusting the High Voltage (HV) and Pulse Height Analyzer (PHA) settings for the SC.
Procedure for aligning optics when using the optional D/teX Ultra detector.
Procedure for aligning optics when only the D/teX Ultra detector is used.
Instructions for setting discriminator values for the D/teX Ultra detector.
Setting the measurement environment, particularly when the X-ray tube type has been changed.
Procedure for setting up real-time 2 theta axis correction for initial setup or periodic inspection.
Step-by-step guide for powering on and initializing the MiniFlex 600 system.
Procedures for safely powering off the MiniFlex 600 system and its components.
Methods for preparing powder and block samples on various sample plates.
Explanation of the slit system and the procedure for slit correction.
Steps for conducting a general measurement using the MiniFlex Guidance software.
Details on setting measurement conditions for qualitative analysis using SC and D/teX Ultra detectors.
Information on replacing the X-ray tube, cleaning filters, and general care for SC.
How to check and interpret alarm information displayed by the system.
Instructions for installing sample rotation attachments and automatic sample changers.
Procedure for installing the optional counter monochromator for improved data quality.
Notes on optics alignment and absorber usage when the counter monochromator is installed.
Diagram and explanation of the slit arrangement when using the counter monochromator.