Do you have a question about the Rigol DM3051 and is the answer not in the manual?
Brand | Rigol |
---|---|
Model | DM3051 |
Category | Multimeter |
Language | English |
Inspect the new DM3000 Digital Multimeter for damage and check accessories.
Adjust the handle position for viewing and carrying the multimeter.
Familiarize with the front and rear panels, buttons, and user interface of the DM3000.
Step-by-step guide for connecting and measuring DC voltage with the DM3000.
Step-by-step guide for connecting and measuring AC voltage with the DM3000.
Step-by-step guide for connecting and measuring DC current with the DM3000.
Step-by-step guide for connecting and measuring AC current with the DM3000.
Learn how to measure resistance using 2-wire and 4-wire methods with the DM3000.
Guide on connecting and measuring capacitance using the DM3000.
Procedure for performing continuity tests with the DM3000 multimeter.
Steps to check diodes using the DM3000's diode test function.
How to measure frequency and period using the DM3000's measurement functions.
Guide on setting up and performing sensor measurements with the DM3000.
How to adjust the reading resolution (accuracy) of the DM3000.
How to set the number of digits displayed on the DM3000.
Select manual or automatic range options for measurements on the DM3000.
Configure trigger modes (Auto, Single, Hold) for data acquisition.
Configure various measurement parameters like continuity, filter, impedance, null, and ratio.
Utilize math functions like statistic, dB, dBm, and limit testing for advanced analysis.
Configure triggering modes (Auto, Single, Hold, External) for precise data acquisition.
Save and load measurement data, parameters, and sensor files to local or USB storage.
Configure system settings, interface parameters (LAN, GPIB, USB, RS232), and calibration.
Configure high-speed data logging and multi-route scanning using the inspection module.
Access the integrated help system for button descriptions and operational guidance.
Obtain the statistic of the maximum value read in a measurement.
Eliminate test lead resistance error when measuring smaller resistances.
Perform dBm measurements by setting resistance value as the dBm setting value.
Perform dB measurements by setting resistance value as the dBm setting value.
Perform pass/fail testing using upper and lower limits for DC voltage measurements.
Set up and use a temperature sensor project for measurements.
Capture and hold stable readings on the front panel display using the Reading Hold function.
Lists common prompting messages and their explanations for user guidance.
Provides solutions for common issues like blank screen or incorrect readings.
Detailed accuracy specifications for DC and AC measurements of DM306x models.
Detailed accuracy specifications for DC and AC measurements of DM305x models.
Lists standard and optional accessories included with the DM3000 series.
Details the manufacturer's warranty policy for RIGOL products.
Provides guidelines for the general care and cleaning of the instrument.
Contact information for RIGOL support, service, and sales.