Users Guide RIGOL
Publication number: UGC01107-1110
Dec. 2008
DM3000 Series Digital Multimeter
DM3061/2/4
DM3051/2/4
© 2007 RIGOL Technologies, Inc. All Rights Reserved

Table of Contents

Other manuals for Rigol DM3051

Question and Answer IconNeed help?

Do you have a question about the Rigol DM3051 and is the answer not in the manual?

Rigol DM3051 Specifications

General IconGeneral
BrandRigol
ModelDM3051
CategoryMultimeter
LanguageEnglish

Summary

CHAPTER 1 QUICK START

General Inspection

Inspect the new DM3000 Digital Multimeter for damage and check accessories.

Handle Adjustment

Adjust the handle position for viewing and carrying the multimeter.

The Front/Rear Panel and User Interface

Familiarize with the front and rear panels, buttons, and user interface of the DM3000.

To Measure DC Voltage

Step-by-step guide for connecting and measuring DC voltage with the DM3000.

To Measure AC Voltage

Step-by-step guide for connecting and measuring AC voltage with the DM3000.

To Measure DC Current

Step-by-step guide for connecting and measuring DC current with the DM3000.

To Measure AC Current

Step-by-step guide for connecting and measuring AC current with the DM3000.

To Measure Resistance

Learn how to measure resistance using 2-wire and 4-wire methods with the DM3000.

To Measure Capacitance

Guide on connecting and measuring capacitance using the DM3000.

To Test Continuity

Procedure for performing continuity tests with the DM3000 multimeter.

To Check Diodes

Steps to check diodes using the DM3000's diode test function.

To Measure Frequency and Period

How to measure frequency and period using the DM3000's measurement functions.

To Make an Sensor measurement

Guide on setting up and performing sensor measurements with the DM3000.

To Choose Digits resolving index

How to adjust the reading resolution (accuracy) of the DM3000.

To Choose Data Digit Display

How to set the number of digits displayed on the DM3000.

To Choose Range Options

Select manual or automatic range options for measurements on the DM3000.

To Control Trigger Options

Configure trigger modes (Auto, Single, Hold) for data acquisition.

CHAPTER 2 OPERATING YOUR MULTIMETER

To Set up Measurement Parameters

Configure various measurement parameters like continuity, filter, impedance, null, and ratio.

To Make Mathematics Operation

Utilize math functions like statistic, dB, dBm, and limit testing for advanced analysis.

To Set up Trigger System

Configure triggering modes (Auto, Single, Hold, External) for precise data acquisition.

To Save and Recall

Save and load measurement data, parameters, and sensor files to local or USB storage.

To Set Up Utility

Configure system settings, interface parameters (LAN, GPIB, USB, RS232), and calibration.

To Set up High-speed data acquisition and Multi-route Scanning

Configure high-speed data logging and multi-route scanning using the inspection module.

Use the built-in help system

Access the integrated help system for button descriptions and operational guidance.

CHAPTER 3 APPLICATION EXAMPLES

Example 1: Reading Statistic Functions

Obtain the statistic of the maximum value read in a measurement.

Example 2: Elimination Leads Resistance Error

Eliminate test lead resistance error when measuring smaller resistances.

Example 3: dBm Measurement

Perform dBm measurements by setting resistance value as the dBm setting value.

Example 4: dB Measurement

Perform dB measurements by setting resistance value as the dBm setting value.

Example 5: Limit Test

Perform pass/fail testing using upper and lower limits for DC voltage measurements.

Example 6: Temperature Sensor

Set up and use a temperature sensor project for measurements.

Example 7: Reading Hold

Capture and hold stable readings on the front panel display using the Reading Hold function.

CHAPTER 4 PROMPT MESSAGES& TROUBLESHOOTING

Prompting Message

Lists common prompting messages and their explanations for user guidance.

Troubleshooting

Provides solutions for common issues like blank screen or incorrect readings.

CHAPTER 5 CHARACTERISTICS

Characteristics for DM306x

Detailed accuracy specifications for DC and AC measurements of DM306x models.

Characteristics for DM305x

Detailed accuracy specifications for DC and AC measurements of DM305x models.

CHAPTER 6 APPENDIX

Appendix A: DM3000 Series Accessories

Lists standard and optional accessories included with the DM3000 series.

Appendix B: Warranty

Details the manufacturer's warranty policy for RIGOL products.

Appendix C: General Care and Cleaning

Provides guidelines for the general care and cleaning of the instrument.

Appendix D: Contact RIGOL

Contact information for RIGOL support, service, and sales.