EasyManuals Logo

Rinnai Enduro XL SP250B User Manual

Rinnai Enduro XL SP250B
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Issue
1
Operation Installation Manual
Low Profile Roof Mounted
Solar Hot Water Systems
This system shall be installed in accordance with:
• Manufacturers Installation Instructions
• Current AS/NZS 3500
All applicable local rules and regulations including local OH&S requirements
This system must be installed, commissioned and serviced by an Authorised Person.
Not suitable as a pool or spa heater.
The solar hot and solar cold pipes between the solar storage tank
and the solar collector(s) must be copper tube. Fittings used to
join these pipes must use metallic materials to acheive sealing.
Plastic pipe and fittings must not be used as they are not suitable
for the high temperatures and pressures that may occur.
Failure of plastic pipe and/or fittings can lead to the release of high
temperature water and can cause sever flooding and water damage.
IMPORTANT
This system is fully certified in its own right. Given the unique nature of the
installation for this system it is reccomended to discuss any additional site
requirements with the site Building Inspector / Surveyor.
Issue
1
All Rinnai gas products
are A.G.A. certified.
W169
SAI Global
AS/NZS 2712
Lic No.1849
SAI Global

Other manuals for Rinnai Enduro XL SP250B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai Enduro XL SP250B and is the answer not in the manual?

Rinnai Enduro XL SP250B Specifications

General IconGeneral
CategoryTankless
Maximum BTU Input199, 000 BTU
Minimum BTU Input15, 000 BTU
Maximum BTU199000 BTU
Minimum BTU15000 BTU
VentingPVC/CPVC

Related product manuals