CP1/2/4 - 5
Fig. 4 - CPU Board
Fig. 5 - POWER Control Panel
POWER Board
Adress
10.1
10.2
M10
M12M2M3M1
M5
M15
M13M9M7M4
M11
J6
J5
J4
J3
J2
S1
J1
F4
F2
F6
F3
SW1
P1
TR1
TR2
+
-
+
-
+
-
TR3
P2
J7
15.215.1
13.59.99.89.79.69.59.49.39.29.17.67.57.47.37.27.14.54.44.34.24.1
11.4
11.3
11.2
11.1
13.4
13.3
13.2
13.1
M6
5.2 6.6 6.5 6.4 6.3 6.2 6.15.1
10.3
10.4
12.4
12.3
12.2
12.12.33.43.33.23.11.51.41.31.21.1 2.22.1
INVERSION PROTECT
RESERVED
RESERVED
SERIAL 485 B0 ( 7)
SERIAL 485 A0 ( 6)
RESERVED
RESERVED
RESERVED
RESERVED
IGNORE SAFETY
TRIMMER 3 RANGE
ANTI REFRESH
COM
LOOP INPUT 2
LOOP INPUT 3
LOOP INPUT 4
ALL UP
ALL DOWN
STEPbySTEP 4
STEPbySTEP 3
STEPbySTEP 2
STEPbySTEP 1
COM IN Control
LOOP 1 INPUT / MASTER
LOOP 1 INPUT / MASTER
+ 24Vdc Relè Light
GREEN Light
RED Light
GND
+ 24 Vdc FIX
3°CH RADIO S/S 24V 2A
3°CH RADIO S/S 24V 2A
- GND Aux
19 Vac In AUX
19 Vac In AUX
+ 27V Battery AUX
+ 24 Vdc IN 1 Supply
+ 24 Vdc IN2 Supply
- GND Supply 1
- GND Supply 2
(1+2) +32Vdc OUT Supply 1
(9+10+11) - OUT GND 1
(1+2) +32Vdc OUT Supply2
(9+10+11) - OUT GND 2
- GND Battery
- ALARM 24Vdc/1A
+ ALARME24Vdc/1A
RESERVED
RESERVED
(3) MOTOR EMERGENCY +24 Vdc
(5) BRAKE 1 EMERGENCY +24 Vdc
BRAKE 2 EMERGENCY +24 Vdc
BRAKE 3 EMERGENCY +24 Vdc
BRAKE 4 EMERGENCY +24 Vdc
+27,5 Vdc Charge Battery
- GND Charge Battery
(4) EMERGENCY CONTROL +24Vdc
EA Phase A Encoder [White]
EB Phase B Encoder [Blue]
+5 Vcc Encoder [Red]
-GND Encoder [Black]
- Ext. siren (F White)
+ Ext. siren (F Brown)
- Anti-frost resistance
+ Anti-frost resistance
[F 3] + Motor in emergency status
[F 4] + Emergency control
[F 5] + Brake in emergency status
- Brake with linings
+ Brake with linings
(F White) + Motor output
(F Brown) - Motor output
Earth
Yellow/Green earth lead
connected to motor sheath
or internal cylinder
1
Address B
Address A
Soft STOP
Beacon
0
1
2
0 = Normal (Maximum strength)
1 = Sensitive (Stops immediately when rising)
0: LED flashing normally
1: Beacon off when bollard fully raised
3 4
B A
0 0 Bollard 1 (F0)
POWER
Board address
0 1 Bollard 2 (F1)
1 0 Bollard 3 (F2)
1 1 Bollard 4 (F3)
1
Address B
Address A
Soft STOP
Beacon
0
1
2
0 = Normal (Maximum strength)
1 = Sensitive (Stops immediately when rising)
0: LED flashing normally
1: Beacon off when bollard fully raised
3 4
B A
0 0 Bollard 1 (F0)
POWER
Board address
0 1 Bollard 2 (F1)
1 0 Bollard 3 (F2)
1 1 Bollard 4 (F3)
DIAGNOSTIC AND EMERGENCY LOWERING - RED BUTTON