JUNE 2022
WALL CHARGER
Installation Guide
PRODUCT NUMBER PT00057325
Question and Answer IconNeed help?

Do you have a question about the RIVIAN PT00057325 and is the answer not in the manual?

Summary

Important Safety Instructions

Precautions

General precautions and safety symbols used in the document.

Risk of Electrical Shock

Details and warnings regarding the risk of electric shock during installation and use.

Risk of Personal Injury

Information on preventing personal injury during installation and operation.

Safety Symbols on Hardware Labels

Explanation of safety symbols found on the hardware labels.

Risk of Damage to Equipment

Guidelines to prevent damage to the Wall Charger and associated equipment.

Introduction

Identify Parts

Lists and identifies all components included with the Rivian Wall Charger.

Tools

Remove the Faceplate

Installation

Select an Installation Location

Guidelines for choosing an optimal and safe location for the Wall Charger.

Attach the Mounting Plate

Attach the Wall Charger to the Mounting Plate

Set the Operating Current

Connect Conductors

Install the Faceplate

Wrap and Dock the Cable

Connect to Wi-Fi

What You Need

Lists the necessary items and conditions for connecting the Wall Charger to Wi-Fi.

Connect to the Wall Charger

Step-by-step instructions for pairing the Wall Charger with a Rivian account using the app.

Light Bar States

Troubleshooting

Power Off the Wall Charger

Remove the Wall Charger

Specifications

Supplemental Information for Electrical Service Wiring

240 V Split-Phase System

Diagram and explanation of the 240V split-phase electrical system used.

FCC Interference Statement

RF Exposure Information

Industry Canada Statement

RADIATION EXPOSURE STATEMENT

Customer Service

RIVIAN PT00057325 Specifications

General IconGeneral
Voltage208/240 VAC (-20% – +15%), single-phase
Frequency60 Hz
Metering accuracyEmbedded ± 1%
Charging connectorSAE J1772
Charging cable length25 ft (7.6 m)
Wi-FiIEEE 802.11 b/g/n
Network band2.4 GHz
Ethernet10/100BASE-T
BluetoothSupports Bluetooth 5.0
Data protocolOCPP 1.6; ISO 15118 capable
Real-time clockYes (7 days)
Wiring typeHard-wired
Acceptable conductor sizes#14 to #6 AWG copper only (#6 AWG required for full 48 A continuous current)
Operating temperature-22°F to 122°F (-30°C to 50°C)
Storage temperature-40°F to 176°F (-40°C to 80°C)