EasyManua.ls Logo

Rocal DROP X1320 - Technical Specifications; Breakdown of Delivered Components

Rocal DROP X1320
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
pag. 10
1.1 Technical specifications
Parameter
Value
Minimum - Maximum draught 11-13 Pa
Fuel consumption 2,7 kg/h
Smoke mass flow rate 12 g/s
Performance 82 %
Nominal output 9 kW
Maximum power 15 kW
Average CO concentration at 13% of O2 0,10%
Particle concentration 28 mg/Nm
3
Payload (trial) 2,1 kg
Reload interval period (trial) 47 min
Medium draft (trial) 12 Pa
Net weight 148 kg
Maximum authorized load (fuel) 5 kg
Reload height 200 mm
Logs length 300 mm
Minimum flue height 4000 mm
Flue duct 176 x 166 mm
Ø Air inlet 100 mm
Front safety distance 1000 mm
Side safety distance 300 mm
Back safety distance 200 mm
Primary register (trial) 15% open
Secondary register (trial) 60% open
Average temperature of smoke 159º C
Type of combustion INTERMITTENT
Flue liner NOT SHARED
Fuel NATURAL WOOD
Humidity fuel logs 12-20% - two years under cover
Certification year 2015
Certificate No.:
-
0151/15
-
1
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED
document)
1.
Fireplace’s body
2.
Flue liner connector
3.
Back trim of the ceiling plate
4.
Front trim of the ceiling plate
5.
The body of the telescopic ceiling plate
6.
Body of the ceiling plate
7.
Tool for handling registers and opening door
8.
Upper baffle to limit the draught
9.
Aluminium ring to connect
10.
Flat string for the ceiling plate
11.
Heat-resistant glove
12.
Cleaning cloth
13.
Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
14.
Metal clamp
15.
Bag with metallic anchors
16.
Heat-resistant spray paint for touch-ups
17.
Bag with screws and anchors
18.
Fixative of the aluminium ring
19.
Exterior air inlet cover
1. SPECIFICATIONS

Related product manuals