pag. 10
1.1 Technical specifications
Minimum - Maximum draught 11-13 Pa
Fuel consumption 2,7 kg/h
Smoke mass flow rate 12 g/s
Performance 82 %
Nominal output 9 kW
Maximum power 15 kW
Average CO concentration at 13% of O2 0,10%
Particle concentration 28 mg/Nm
3
Payload (trial) 2,1 kg
Reload interval period (trial) 47 min
Medium draft (trial) 12 Pa
Net weight 148 kg
Maximum authorized load (fuel) 5 kg
Reload height 200 mm
Logs length 300 mm
Minimum flue height 4000 mm
Flue duct 176 x 166 mm
Ø Air inlet 100 mm
Front safety distance 1000 mm
Side safety distance 300 mm
Back safety distance 200 mm
Primary register (trial) 15% open
Secondary register (trial) 60% open
Average temperature of smoke 159º C
Type of combustion INTERMITTENT
Flue liner NOT SHARED
Fuel NATURAL WOOD
Humidity fuel logs 12-20% - two years under cover
Certification year 2015
Certificate No.:
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED
document)
Fireplace’s body
Flue liner connector
Back trim of the ceiling plate
Front trim of the ceiling plate
The body of the telescopic ceiling plate
Body of the ceiling plate
Tool for handling registers and opening door
Upper baffle to limit the draught
Aluminium ring to connect
Flat string for the ceiling plate
Heat-resistant glove
Cleaning cloth
Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
Metal clamp
Bag with metallic anchors
Heat-resistant spray paint for touch-ups
Bag with screws and anchors
Fixative of the aluminium ring
Exterior air inlet cover