14
5.2.4. Painting.
The heatproof paint that covers the inside and outside of the appliance withstands temperatures up to
600 °C and releases a subtle typical smell that disappears after the first few uses.
It is possible for the paint to jump out in some areas inside the housing after a period of use, due to corrosion caused
by liquids, inadequate fuel types or others not authorized by the manufacturer, etc., In that case it will be necessary to
repaint all damaged areas before a prolonged shutdown period. (Use exclusively
"Rocal heatproof spray paint”.
Below is a table of possible anomalies, their causes and solutions:
or insufficient draught
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply.
Simultaneous operation with other ventilation
devices and / or heating
Setting the register
glass
Incorrect duct
Inappropriate fuel
Overly closed registers
Revise section on insufficient flue
(below).
Use recommended fuel
Adjust registers
colour fading of the
plate
Excessive temperature caused by
excessive heat in the combustion
chamber
Check the fuel load avoiding overheating
Adjust registers
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong
position
Use recommended fuel
Adding fuel
Adjust registers
or gases from the front,
bad smell
First lighting
Flammable or combustible items in the
enclosure or surrounding walls of the
equipment
Crack in the combustion chamber of the
equipment
Wait for the polymerization process of the
paint to finish; this can take from one to
several lightings.
Review of insulating materials such as
fiberglass, fireproof wood or any inflammable
elements and replace them.
Check for tightness and if you discover a
crack, please contact your dealer.
Incorrect duct
Combustion control registers in the wrong
position
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
Incorrect duct
Duct dirtiness
Open the primary and secondary register
following the steps outlined in the manual.
Should this not have an effect, check that the
flue duct is clean; if it is not clean, contact a
professional to clean this. If the problem
persists contact your dealer.
6. PROBLEMS: CAUSE AND SOLUTION