A. Disconnect RDAT & Power from the main unit.
B. Remove Cover from main unit by unscrewing the six hex head screws with the 3/32" Allen wrench supplied with the EPX
2
.
C. Remove 2 Jumpers on connector P5 corresponding to LOL, LRL, LOR & LRR.
D. Remove the Top Half of the 2 Standoffs carefully by hand from the main unit. It is not necessary to remove the top screws
when separating the standoff into its segments.
MAN-0953-C
©5/97
®®
E. Install E14 carefully into header connections P3, P4 and P5.
F. Replace 2 Top Standoffs, with screws intact, carefully by hand. (
Do Not Overtighten.
)
G. Replace Cover on the main unit with the six hex head screws.
H. Reconnect RDAT & Power to main unit.
I. Adapt E14 Software by selecting DCard from the Setup menu and select E14 or refer to page 36 of your EPX
2
Manual.
J. Congratulations! You have successfully installed your optional Equalizer Module.
ATTENTION: To maintain your EPX
2
warranty, we recommend your Authorized Rockford Fosgate Dealer install your new accessory.
INSTALLING THE OPTIONAL SYM-E14 DCARD
® ®
P4
P5
P3
BB
B
B
A
B
D
C
D
P4
P5
P3
F
E
F
EE
EE
E

Other manuals for Rockford Fosgate SYMMETRY EPX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockford Fosgate SYMMETRY EPX2 and is the answer not in the manual?

Rockford Fosgate SYMMETRY EPX2 Specifications

General IconGeneral
BrandRockford Fosgate
ModelSYMMETRY EPX2
CategoryCrossover
LanguageEnglish

Related product manuals