Installation Instructions
Original Instructions
ArmorKinetix 2090 Cables and Connectors
Catalog Numbers 2090-CDHIFS-12AF, 2090-CDHP1S-12AF, 2090-CSBM1P7-14AF, 2090-CPWFLP7-14AF, 2090-CFBM7S7-CDAF, 2090-CFBFLS7-CDAF,
2090-CDET, 2090-CDHT, 2090-CDFT, 2090-CDPT
Cable Catalog Numbers
Catalog numbers consist of various characters, each of which identifies a specific option for that component. Use the catalog numbering charts below to understand the
configuration of your component. For the cable type: PUR = Polyurethane and TPE = Thermoplastic Elastomer.
ArmorKinetix PIM to ArmorKinetix DSx Hybrid Cables
This cable connects the ArmorKinetix® Power Interface Module (PIM) to either the ArmorKinetix Distributed Servo Motor (DSM) or the Distributed Servo Drive (DSD).
Topic Page
Cable Catalog Numbers 1
Before You Begin 3
ArmorKinetix Cable System Overview 4
Guidelines for Cable and Connector Installation 5
ArmorKinetix PIM to DSx Hybrid Cable Installation 5
ArmorKinetix DSx to DSx Hybrid Cable Installation 6
ArmorKinetix DSD to Kinetix VPL/MPL Motor Power/Feedback Cable Installation 7
ArmorKinetix DSD to Induction Motor Power Cable Installation 7
ArmorKinetix DSD to Kinetix Motor Feedback Cable Installation 8
ArmorKinetix DSD to Induction Motor and Auxiliary (stand-alone) Feedback Cable Installation 8
ArmorKinetix 2090 Hybrid Connector Communication Extension 9
Cable Bend Radius Specifications 9
ArmorKinetix Cables Environmental Specifications 10
Additional Resources 10
2090 - C DH IF S - 12 AF xx xx
Length Increments
P1 = 0.1 m, P2 = 0.2 m, P3 = 0.3 m, P4 = 0.4 m, P5 = 0.5 m,
P6 = 0.6 m, P7 = 0.7 m, P8 = 0.8 m, P9 = 0.9 m, Blank = 0
Length
(a)
xx = 3…50 m
Cable Type
AF = TPE, Continuous-flex
Wire Gauge
12 AWG
Downstream Connector
S = SpeedTec (socket)
Upstream Connector
IF = PIM end flying leads
Cable Type
DH = Hybrid
Accessory
C = Cable
Bulletin
(a) For 3 m to 5 m cable lengths, cables are available in 0.1 m
increments. For cable lengths longer than 5 m, cables are
available in 0.5 m increments.