9
• Shake the spray tube after manually opening the valve handle. It is forbidden to spray one place
only to avoid chemical damage.
• The practitioner should not perform the operation against the wind.
• The spray tube should be shaken to the right and left while spraying. At the same time, the
practitioner must continue to progress.
Double Conical Mist Nozzle
MAINTENANCE AND REPAIR
• After daily work, maintenance should always be done.
• Clean the machine surface.
• Clean and rinse the tank with clean water.
• Check all connections for leaks. If there is a leak, the necessary actions must be taken to eliminate
it.
• Check all screws and tighten any loose ones. Replace those that need replacement immediately.
• After maintenance and repair, the machine should be stored in a dry and well ventilated place.
• It should be kept away from flammable materials and sunlight.
• Carefully clean the machine surface.
• Plastic parts should not be exposed to the sun and pressure should not be applied with hard
objects.
• Store the machine in a clean, dry place and cover it with a cloth.
• If the tool fails despite careful production and testing methods, the repair should be made by an
authorized service for “RODEX” power tools.
TROUBLESHOOTING
Motor fails to start
after being powered
on.
Power cable disconnected.
Battery is not charged.
Damaged power switch.
Dismantle base to reconnect cables
Charge battery.
Replace switch.
Fastening screws of pump are
loose.
Leakage occurring at
bottom of sprayer
base.
Inlet and/or outlet tubes of
pump are damaged or not
securely connected.
Dismantle base and tighten tube clamps,
and/or replace tubing.
Clogged spray nozzle.
Spray nozzle worn out.
Spray sheet inverted.
Clogged filter screen.
Tubes not securely connected.
Battery low on power.
Air remaining in pump.
Clean nozzle.
Replace spray nozzle.
Place it correctly.
Clean.
Tighten.
Alarm not working– replace and
recharge.
Remove nozzle or spray rod to discharge
air.