EasyManua.ls Logo

Rohde & Schwarz RTP164 - Page 1626

Rohde & Schwarz RTP164
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1626User Manual 1337.9952.02 ─ 12
TRIGger<m>:CAN:NDBYtes?
Returns the number of data bytes defined by DLC. DLC and NDB are different in CAN
FD for DLCs > 8.
See also: "Data setup: DLC, NDB, Transfer, Condition, Data min, Data max"
on page 568.
Return values:
<NDBytes> Range: 1 to 64
Increment: 1
*RST: 1
Usage: Query only
TRIGger<m>:CAN:FDATa:DPOPerator <DataPosOperator>
Sets the operator to define an exact position or a data range where the instrument
looks for the specified data pattern.
The setting is available in CAN FD option R&S RTP-K9.
The position can be defined if the data field of the frame is longer than 8 bytes - if
TRIGger<m>:CAN:DLC9.
Parameters:
<DataPosOperator> ANY | OFF | EQUal | GETHan | INRange | RANGe
ANY = OFF
The data position is not relevant for the trigger condition.
EQUal | GETHan
Equal, Greater or equal than. These conditions require one data
position to be set with TRIGger<m>:CAN:FDATa:DPOSition.
INRange = RANGe
In range: Set the minimum and maximum value of the range with
TRIGger<m>:CAN:FDATa:DPOSition and TRIGger<m>:
CAN:FDATa:DPTO.
*RST: ANY
TRIGger<m>:CAN:FDATa:DPOSition <DataPosition>
Defines the number of the first data byte at which the data pattern may start.
The setting is available in CAN FD option R&S RTP-K9.
Parameters:
<DataPosition> Range: 1 to 57
Increment: 1
*RST: 1