R&S ZVH Cable and Antenna Test Mode
Configuring Cable and Antenna Tests
Operating Manual 1309.6946.12 - 09 55
Setting the reference position
The reference position defines the position of the reference line in the diagram. The
reference position is a linear value between 0 and 10. Each value represents one
horizontal grid line of the diagram. 0 corresponds to the top grid line and 10
corresponds to the bottom grid line.
When you change the reference position, the R&S ZVH also shifts the position of the
trace by the magnitude of the reference position change. It has no effect on the
reference value itself.
Press the SCALE/AMPT key.
Press the "Range/Ref Pos" softkey.
Select the "Ref Position:" menu item.
Enter the reference position you want.
The R&S ZVH moves the trace accordingly.
2.2.3.2 Setting the Attenuation
The R&S ZVH provides functions to attenuate the signal at the RF input.
Press the "Receiver Att" softkey.
Enter the attenuation of the signal at the RF input.
You can set an RF attenuation in the range from 0 dB to 40 dB in 5 dB steps.