    What to do if powder does not adhere to object with Romer PROTON II Industrial Equipment?
    • J
      Jason FarmerAug 12, 2025
      If the powder isn't sticking to the object even when the gun is spraying, it could be due to several reasons. First, check the high voltage and current settings to ensure they are properly activated. Second, verify that the objects are correctly grounded. If the issue persists, the high voltage cascade might be defective, requiring the gun to be sent in for repair.
  • D
    Debbie BallAug 27, 2025
    What to do if I see H11 error on Romer PROTON II Industrial Equipment?
    • G
      Gwendolyn WrightAug 27, 2025
      If you're seeing an H11 error message on your Romer Industrial Equipment control unit, it could be due to a few reasons. First, ensure that the gun is properly connected. If it is, the gun plug or gun cable might be defective, requiring replacement or repair. Alternatively, the remote control on the powder gun could be defective, in which case you should replace the remote control (gun cap).
  • J
    Jamie YangSep 3, 2025
    Why does the gun LED remain dark on my Romer PROTON II Industrial Equipment?
    • C
      Christopher BarnesSep 3, 2025
      If the gun LED on your Romer Industrial Equipment remains dark even when the gun is triggered, it could be due to a few reasons. First, check if the high voltage adjustment is set too low and increase it if necessary. Second, the gun plug or gun cable might be defective, requiring replacement or repair. Finally, the LED on the gun itself might be defective, requiring replacement of the gun back cover.
  • B
    buckdavidNov 18, 2025
    How to fix a Romer Industrial Equipment gun that doesn't spray powder?
    • S
      Sarah ReynoldsNov 18, 2025
      If your Romer Industrial Equipment gun isn't spraying powder despite being switched on and triggered, there are several potential causes: 1. Ensure the equipment is connected to a compressed air source. 2. Increase the powder output and/or total air volume on the control unit if there is too little conveying air. 3. Check and clean the injector or nozzle on the injector, powder hose, or powder gun for any clogs. 4. Replace or insert the insert sleeve in the injector if it's worn or missing. 5. Replace the nozzle in the injector if it is clogged. 6. Replace the motor throttle if fluidizing isn't running. 7. Replace the solenoid valve if there's no conveying air due to a defective motor throttle. 8. If none of these steps work, the solenoid valve or front plate might be defective, r...