ROOTECH ACCURA 2300S Series User Manual

ROOTECH ACCURA 2300S Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ACCURA 2300S/2350-1P3FSC
Data Center Distribution Panel Digital Power Meter/
Single-Phase Three Feeder Power Measuring Module
Actually makes possible data center energy management
User Guide[English]
Revision 1.20 2019/02/15

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ROOTECH ACCURA 2300S Series and is the answer not in the manual?

ROOTECH ACCURA 2300S Series Specifications

General IconGeneral
Measurement Range-50°C to 2300°C (-58°F to 4172°F)
Distance to Spot Ratio50:1
Power Supply9V Battery
Resolution0.1°C/°F
EmissivityAdjustable 0.10 to 1.00
Spectral Response8 to 14 µm
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)

Summary

Notice

Installation Considerations

Provides guidelines and precautions for safe installation of the devices.

Warranty Information

Limitation of Warranty

Specifies the conditions and exclusions applicable to the product warranty.

Chapter 2 Installation

Step 1: Mounting Procedures

Explains the procedures for mounting the Accura 2300S and 2350 modules.

Step 2: Accura 2300S Wiring

Details the voltage and digital input/output wiring for the Accura 2300S.

Step 3: Accura 2350-1P3FSC Wiring

Describes the through-hole wiring process for the Accura 2350-1P3FSC module.

Step 4: Accura 2350-1P3FSC-DIZCT Wiring

Explains the wiring for the Accura 2350-1P3FSC-DIZCT option module, including digital input.

Step 5: Communication Combination

Illustrates the communication setup between Accura 2300S and 2350 units.

Step 6: External Communication Setup

Covers Ethernet and RS-485 communication setup for the Accura 2300S.

Step 7: Power Supply and Grounding

Details the power supply connections and grounding requirements for the Accura 2300S.

Chapter 3 Accura 2350-1P3FSC Operation and Setup

Connection and Load Direction Setup

Explains how to configure the connection and load direction settings.

Chapter 4 Accura 2300S Operation and Setup

Module ID Management

Details how to update and auto-assign module IDs for connected Accura 2350 units.

Event Log Mode

Describes how to access and clear event logs.

RS-485 Communication Setup

Details the configuration settings for RS-485 communication.

Ethernet Communication Setup

Covers IP address, subnet mask, gateway, and MAC address configuration.

Reset Functions

Explains how to perform demand, min/max, energy, and all resets.

Chapter 5 Measurement Description

Voltage Connection Measurements

Details voltage, current, and power measurements for various voltage connections.

Dip and Swell Measurement

Explains how voltage dips and swells are detected and measured.

Appendix A Specifications

Accura 2300S Specifications

Lists the specifications for the Accura 2300S power meter.

Accura 2350-1P3FSC Specifications

Provides specifications for the Accura 2350-1P3FSC module.

Appendix C Accuracy and Reliability

Measurement Accuracy Details

Details the accuracy specifications for various measurements.