Do you have a question about the ROOTECH Accura 2350-3P-250A-105 and is the answer not in the manual?
Model | Accura 2350-3P-250A-105 |
---|---|
Category | Control Unit |
Phase | 3 |
Current Rating | 250A |
Voltage Rating | 105V |
Input Voltage | 105V |
Output Current | 250A |
Explains the meaning of caution, warning, and note symbols used in the manual.
Provides essential guidelines for safe installation and operation of the device.
Details the terms and conditions under which the product warranty is not applicable.
Introduces Modbus RTU and TCP protocols used in Accura 2300S.
Details the structure of Modbus RTU and Modbus TCP packets.
Covers Modbus support including Unit ID and Function Codes.
Explains multiple connection policies and access end policies for Modbus TCP.
Describes specific packet structures for Modbus Function Codes 3, 6, 16, and 101.
Configuration details for Digital Output (DO) setup in Accura 2300S.
Configuration parameters for Dip and Swell detection settings.
Covers ID, Management, General, and Extended setup for Accura 2350 modules.
Provides detailed mappings for various Accura 2350 setup configurations.
Provides an overview of the Accura 2300S Modbus map structure and categories.
Details system information for Accura 2300S and Accura 2350 modules.
Covers various setup configurations including Remote, General, Network, NTP, and Measurement.
Configuration details for Digital Output (DO) setup in Accura 2300S.
Configuration parameters for Dip and Swell detection settings.
Configuration for setting the Module ID for Accura 2350 devices.
Procedures for managing Accura 2350 modules within the system.
Covers general setup parameters for Accura 2350 modules.
Details extended setup options for Accura 2350 modules.
Detailed Modbus register maps for Accura 2350 general setups.
Detailed Modbus register maps for Accura 2350 extended setups.
Configuration for energy level settings in Accura 2350 modules.
Configuration parameters for data aggregation intervals and settings.
Configuration for grouping Accura 2350-1P modules.
Setup for detecting voltage failure events.
Configuration for Modbus serial communication parameters.
Configuration settings for current-related events.
Configuration settings for temperature-related events.
Configuration settings for leakage current events.
Configuration for managing summer time settings.
Setup for creating and managing user-defined expressions.
Manages device control including Remote Unlock, Measurement Control, and User Interface.
Details extended control functionalities and specific module maps for Accura 2350.
Covers various measurement data categories and collection methods.
Detailed map of voltage measurement data for Accura 2300S.
Detailed maps of measurement data for Accura 2350 modules.
Min/max voltage values and time-stamps for Accura 2300S during aggregation.
Min/max data and time-stamps for Accura 2350 modules during aggregation.
Details voltage and current harmonics data for Accura devices.
Provides voltage and current waveform data for Accura devices.
Covers various types of measurement event data.
Guidance on resolving address and endian errors during data collection.
Details on remote setup unlocking and locking for device configuration.
Details on remote control unlocking and locking for device operations.
Provides a flowchart and steps for collecting measurement data.
Configures the aggregation interval for data collection.
Explains buffer index selection and fetching measurement data.
Confirms validity of voltage and module data before collection.
Details components for user-defined formulas and data formats.
Describes formats for number data and normal operators.
Explains formats for casting operators and end-of-stream markers.
Illustrates a practical example of a user-defined formula calculation.