ACCURA 2300/2350
Distribution Panel Digital Power Meter/Power Measuring Module
Actually makes possible enterprise energy management
User Guide[English]
Revision 1.30 2018/9/17

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ROOTECH ACCURA 2300 Series and is the answer not in the manual?

ROOTECH ACCURA 2300 Series Specifications

General IconGeneral
BrandROOTECH
ModelACCURA 2300 Series
CategoryControl Unit
LanguageEnglish

Summary

Chapter 1 Introduction

Overview

Introduces energy management shift and product role in branch load management.

Application

Details applications in enterprise energy management and CO2 reduction.

Device Lineup

Lists Accura 2300 meter and various Accura 2350 power measuring modules.

Features

Highlights key features like data collection, accuracy, and power quality.

Installation Example

Shows common installation scenarios for modules in distribution boards.

Chapter 2 Installation

Environmental Conditions

Specifies acceptable environmental conditions for device operation.

Meter Overview

Provides visual overview of Accura 2300 front, side, and rear panels.

Components

Lists all included components for Accura 2300 and 2350 modules.

Dimension

Details physical dimensions for Accura 2300 and Accura 2350 modules.

Installation Diagram

Illustrates general installation diagrams for Accura 2300/2350 modules.

Step 1: Mounting

Step-by-step guide for physically mounting the Accura 2300 meter.

Step 2: Accura 2300 Wiring

Provides detailed instructions for Accura 2300 voltage connections.

Step 3: Accura 2350 Current Through-hole Wiring

Details current wiring procedures for Accura 2350 modules.

Step 4: Accura 2300/2350 Combination of Communication

Explains how to combine Accura 2300 and 2350 units for communication.

Step 5: Accura 2300 External Communication

Details external communication options like Ethernet and RS-485.

Step 6: Accura 2300 Power Supply and Ground

Covers power supply and ground connection requirements for Accura 2300.

Chapter 3 Accura 2350 Operation/Setup

Operation Mode

Describes the display and setup modes of the Accura 2350.

Button Operation

Explains the functions of the Accura 2350 buttons for navigation.

Accura 2350-3P[3PSC] Three-phase Power Measuring Module

Details operation and setup for 3-phase Accura 2350 modules.

Setup Mode

Outlines the available setup menus and configuration options.

Phase Sequence/Load Direction Setup

Guides configuration of phase sequence and load direction.

Load Connection Setup

Explains settings for load connections in various configurations.

CT Ratio 0/1K Setup

Details setting CT ratios for specific modules.

Rating Current Setup

Allows selection of the rating current for modules.

Leakage Current Threshold Setup

Configures threshold for leakage current measurement and events.

Accura 2350-1P[1PSC] Single-phase Power Measuring Module

Details operation and setup for single-phase Accura 2350 modules.

Wiring/Load Direction Setup

Explains wiring and load direction settings for different connections.

ID Setup

Guides manual and auto assignment of Module IDs.

Chapter 4 Accura 2300 Operation/Setup

Device Configuration

Describes the physical layout and controls of the Accura 2300.

Operation Mode

Details the three operation modes: Display, Setup, and Event Log.

Display Mode

Explains how to navigate and interpret measurements on the Accura 2300 display.

Measurement Setup

Covers configuration of voltage connection and PT ratings.

Event Setup

Guides configuration of various events like Dip, Swell, Fuse Fail, etc.

Accura 2350 Module ID Setup

Details updating and auto-assigning Accura 2350 module IDs.

Accura 2350-1P Group Device Setup

Explains setting up group devices for three-phase measurements.

Ethernet Communication Setup

Covers configuration of IP, Subnet Mask, Gateway, and NTP settings.

RS-485 Communication Setup

Details configuration of RS-485 communication parameters.

Reset

Explains how to reset various parameters like demand, energy, and all settings.

Digital Input/Output Setup

Guides configuration of digital inputs and outputs.

Display Setup

Covers energy type, Accura 2350 display control, and backlight settings.

Event Log Mode

Explains how to access and interpret event logs.

Button Function

Details the functionality of each button in different modes.

Chapter 5 Measurement Description

General Measurement Factor

Lists general measurement parameters and their support.

Measurement Event Factor

Details the types of measurement events and their log data.

Measurement for Voltage Connection

Explains voltage, current, and power measurements for different voltage connections.

Dip[Sag]/Swell Measurement

Details the process of measuring dips and swells in voltage.

Leakage Current Measurement

Explains methods for measuring leakage current.

Phase Power Measurement

Describes methods for calculating phase power.

Three-phase Total Power Measurement

Explains methods for calculating total power.

Power Factor(PF) Measurement

Details calculation and display of power factor.

Demand Measurement

Explains demand calculation methods.

Unbalance(NEMA MG1)

Details voltage and current unbalance calculations.

Sequence Unbalance

Explains symmetrical components and unbalance ratios.

Aggregation

Describes data aggregation processes and intervals.

APPENDIX A Specification

Accura 2300 Distribution Panel Digital Power Meter

Lists detailed specifications for the Accura 2300 meter.

Accura 2350-3P[1P] Power Measuring Module

Lists detailed specifications for Accura 2350-3P/1P modules.

Accura 2350-3PSC[1PSC] Split-core Power Measuring Module

Lists detailed specifications for split-core modules.

TM-3P[1P] Three-phase[Single-phase] Terminal Module

Lists specifications for terminal modules.

Special- Purpose Modules

Lists specifications for special-purpose modules.

APPENDIX B Standard Compliance

Accuracy

Lists standards related to accuracy.

Power Quality

Lists standards related to power quality.

Safety

Lists safety standards.

EMC

Lists EMC standards.

Certification

Lists certification standards.

General

Mentions warranty period.

APPENDIX C Accuracy/Reliability

Accuracy

Provides detailed accuracy specifications for various parameters.

Power Quality

Lists accuracy for power quality parameters.

Reliability

Lists EMC compliance standards for reliability.

APPENDIX D Ordering Information

Accura 2300 Distribution Panel Digital Power Meter

Lists ordering options for Accura 2300.

Accura 2350-3P[1P, 1PSH] 3-phase[1-phase, 1-phase 1-hole] Power Measuring Module

Lists ordering information for Accura 2350-3P/1P/1PSH modules.

Accura 2350-3PSC[1PSC] Split-core Three-phase[Single-phase] Power Measuring Module

Lists ordering information for split-core 3PSC/1PSC modules.

TM-3P[1P] Three-phase[Single-phase] Terminal Module

Lists specifications for terminal modules.

Special- Purpose Modules

Lists ordering information for special-purpose modules.

Related product manuals