Do you have a question about the Rosemount 5300 Series and is the answer not in the manual?
Measurement Principle | Guided Wave Radar (GWR) |
---|---|
Communication Protocols | HART, FOUNDATION Fieldbus, PROFIBUS PA |
Application | Level and interface measurement |
Accuracy | ±3 mm (±0.12 in) |
Process Temperature Range | -196 to 400°C (-321 to 752°F) |
Process Pressure Range | -1 to 40 bar (-14.5 to 580 psig) |
Probe Types | twin lead |
Output | 4-20 mA with HART |
Enclosure Rating | IP66/IP67, NEMA 4X |
Measurement Range | Up to 50 m (164 ft), depending on probe type |
Approvals | ATEX, IECEx, FM, CSA |
Frequency | 500 MHz to 1.8 GHz |
Explains loop-powered operation and signal output for HART, FOUNDATION Fieldbus, or Modbus.
Provides guidelines for choosing the appropriate probe for Rosemount 5300 Series Transmitter.
Outlines the steps for proper installation of the transmitter.
Highlights safety precautions for personnel performing operations.
Considers mounting requirements, vessel, and process characteristics before installation.
Details how to mount the transmitter with flange or threaded connection.
Highlights safety precautions for personnel performing operations.
States that local regulations and applicable certificates must be observed in hazardous areas.
Provides steps for wiring the transmitter, including cover removal and cable gland tightening.
Highlights safety precautions for personnel performing operations.
Details basic configuration parameters: measurement units, tank geometry, environment, and volume.
Provides steps to configure the transmitter using a Field Communicator.
Explains how to configure using RRM, including Guided Setup and Setup functions.
Details configuration using AMS Suite software for HART communication.
Explains configuration using DeltaV for FOUNDATION Fieldbus.
Highlights safety precautions for personnel performing operations.
Explains using RRM and Echo Curve plot for troubleshooting measurement problems.
Details functions for viewing, recording Echo Curves, and configuring amplitude thresholds.
Discusses issues when the product level is not detected due to high amplitude thresholds.
Addresses issues with detecting reflected signals in interface applications due to low dielectric constants.
Explains how to calibrate analog output by comparing actual current with nominal 4-20 mA.
Details calibration when using nozzles or pipes with physical objects causing disturbances.
Explains how to retrieve device status, errors, warnings, and measurement status.
Covers probe and firmware compatibility and checking versions.
Provides guidance for diagnosing and resolving possible malfunctions.
Lists device status, errors, and warnings that may appear on the display.
Lists error messages displayed on the 5300 Display Panel.
Highlights safety precautions for personnel performing operations.
States SIL 3 capability certification for 4-20 mA Rosemount 5300 Series transmitters.
Describes how the safety function is based on the analog output 4-20 mA.
Specifies installation as a level sensing device compatible with process fluids.
Provides instructions for communicating and verifying configuration using HART.
Covers proof testing, enabling write protection, and site acceptance.
Highlights safety precautions for personnel performing operations.
States SIL 3 capability certification for 4-20 mA Rosemount 5300 Series transmitters.
Details Factory Mutual (FM) approvals for explosion-proof and intrinsically safe models.
Lists ATEX and IECEx approvals with special conditions for safe use.
Highlights safety precautions for personnel performing operations.
Highlights safety precautions for personnel performing operations.
Provides solutions for common communication issues like no communication or incorrect settings.