Do you have a question about the Rossato CN REC 300 IDRO and is the answer not in the manual?

Summary

Combined Dehumidifiers for Radiant Systems

1. Introduction

1.1 Responsibility

Manufacturer's exemption from liability for injuries due to improper use or modifications.

1.2 Explanation of Symbols

Explanation of danger, caution, and information symbols used in the manual.

1.3 Service Rules

Standards for trained operators and safe use of the unit.

1.4 Reference Regulations

Declaration of conformity with relevant safety regulations (CE marks).

1.5 Reception of the Unit

Instructions for checking unit integrity upon delivery and reporting damage.

1.6 Moving and Transporting

Precautions for safely moving and positioning the unit to prevent accidents.

1.7 Unpacking

Guidelines for careful unpacking and proper disposal of packaging materials.

1.8 Intended Use

Defines the unit's purpose as a ducted dehumidifier for radiant systems.

1.9 Interventions and Maintenance

General recommendations for safe and effective maintenance operations.

1.10 General Safety Rules

Essential safety practices, including PPE and fire safety.

2. Description of the Unit

2.1 Range

Overview of the 8 different Ecodry CN REC models and their classifications.

2.2 Air Flows

Description of the 5 predispositions for air channel connection and airflow rates.

2.3 Structure

Details the unit's construction, sound absorption, and panel accessibility.

2.4 Planning Criteria

Information on copper pipe specifications and condensation drain materials.

2.5 Unit Identification

Details on the serial number label and its importance for unit identification.

2.6 Main Components

Description of key components like fans, heat recovery unit, and heat exchangers.

2.7 Diagrams of Devices Disposition

Visual layout of components for different Ecodry CN REC models.

2.8 Options and Functions

Lists standard and optional features and functions available for the units.

3. Refrigeration and Hydraulic Circuits

4. Electrical Circuits

4.1 Electrical Equipments

Information about the electrical panel, wiring, and remote controls.

4.2 Electrical Diagram

Statement that electrical diagrams for all models are provided on subsequent pages.

5. Technical Data

5.1 Table of Technical Data and Operation Limits

Comprehensive table detailing performance specifications for different models.

5.2 Air Flow and Pressure

Graphs illustrating air flow and pressure characteristics for various models.

5.3 Hydraulic Circuit Pressure Drops

Graphs showing pressure drops in the hydraulic circuit based on water flow.

5.4 Dimensions

5.4.1 CN REC 300 (all versions)

Technical drawings with dimensions for the CN REC 300 model.

5.4.2 CN REC 450 (all versions)

Technical drawings with dimensions for the CN REC 450 model.

5.4.2 CN REC 600 (all versions)

Technical drawings with dimensions for the CN REC 600 model.

6. Installation

6.1 Unit Positioning

Guidelines for selecting the installation location and ensuring proper clearance.

6.1.1 Installation of Supply Plenum on CN REC 300 (all models) [optional]

Instructions for mounting the optional supply plenum on CN REC 300.

6.1.2 Mounting Supply Plenum on CN REC 450 (all models) [Optional]

Instructions for mounting the optional supply plenum on CN REC 450.

6.1.3 Mounting Supply Plenum on CN REC 600 (all models) [Optional]

Instructions for mounting the optional supply plenum on CN REC 600.

6.1.4 Unit Fixing on the Wall

Recommendations for wall mounting, including vibration dampers.

6.1.5 Unit Minimum Distance

Minimum clearance requirements for maintenance access for different models.

6.2 Duction

Information on unit ducting for supply and expulsion air.

6.3 Hydraulic Connections

Procedures and requirements for connecting the unit's hydraulic circuit.

6.3.1 Water Circuit Connection

Detailed steps for connecting the water circuit, including required components.

6.3.2 Condensation Drain Connection

Instructions for correctly connecting the condensation drain and siphon.

6.4 Electric Connections

Guidelines for connecting the unit's electrical power supply and cables.

6.4.1 Terminal Block and Wiring

Details on power terminal blocks and user terminal blocks for connections.

6.5 First Commissioning, Calibration and Settings

Calibration PHASE 1

Procedure for setting supply fan speed in the first calibration phase.

Calibration Phase 2

Procedure for calibrating air exchange and related fan speeds.

Calibration Phase 3

Procedure for calibrating circulation, air exchange, and damper settings.

End of Calibration

Final steps after calibration, including power supply and checks.

Setting of Installer Parameters

Instructions for accessing and configuring installer-specific parameters.

7. Display

7.1 Keys

Description of the functions of each key on the unit's control display.

7.2 Main Screen

Explanation of the main display screen and its indicators.

7.3 User Menu

Overview of the 9 screens for basic unit configurations by the end user.

7.4 Alarms Menu

Functionality for displaying and resetting active alarms on the unit.

7.5 Unit Status Menu

Displays detailed operational status and sensor readings of the unit.

7.6 Time Bands Menu

Allows programming time bands for unit operation schedules and settings.

7.7 Other Screens

Access to screens for software version and password modification.

8. Maintenance and Diagnostics

8.1 Events and Faults

Troubleshooting guide for common locking or malfunctioning causes with solutions.

8.2 Maintenance Table

Table outlining scheduled maintenance operations and their recommended periods.

8.3 Ordinary Maintenance

Procedures for regular maintenance, including panel access and filter cleaning.

8.3.1 Exploded View to Identify the Panels to be Opened

Diagrams showing which panels to open for maintenance.

8.3.2 Heat Recovery Cleaning

Instructions for cleaning the heat recovery unit.

8.3.3 Cleaning; Replacement Air Filters

Steps for cleaning or replacing the air filters.

8.4 Extraordinary Maintenance

Guidelines for maintenance tasks requiring specialized personnel.

8.4.1 Heat Exchange Coil Cleaning

Procedure for cleaning the heat exchange coils.

9. Dismantling of the Unit

9.1 Environmental Protection

Procedures for safe dismantling, waste disposal, and environmental protection.

Rossato CN REC 300 IDRO Specifications

General IconGeneral
TypeDehumidifier
ModelCN REC 300 IDRO
Dehumidification Capacity300 L/24h
Operating Temperature Range5-35 °C
Water Tank CapacityNot applicable (condensate drain)