11. Oil Filling and Bleeding
Use Dexron III ATF, or hydraulic fluid that meets ISO32
specifications. Remove fill breather cap and add (10)
ten quarts of fluid. Turn power to on and ensure the
disconnect switch and emergency stop buttons are in
the “ON” position. Proceed with the following steps.
Only skilled and authorized personnel
should be allowed to perform these operations.
Carefully follow all instructions shown below to
prevent possible damage to the car lift or risk of injury
to people.
Be sure that the operating area is cleared of people.
After positioning the lift as specified and performing
electric and hydraulic connections, the lift can be
operated by following the specific procedure.
1. Verify both top limit switches and stop down switch
electrical connections are complete, as shown in Fig. 4
and Fig. 5.
2. Connect hydraulic hoses “A” and “B” to the power
unit as shown in Fig. 7. To connect hoses, remove
closest cover to P1 platform, Fig. 7a.
3. Push the “UP” button until both platforms stop
moving.
4. Add 5 liters more of fluid.
5. Connect the uninstalled hydraulic hoses marked “C”
and “D”, as shown in Fig. 7.
6. Connect the uninstalled hydraulic tube, as shown in
Fig. 7.
7. Push the “UP” button until both platforms stop
moving.
8. Open the cabinet lid and press the “Override
UP” button, as shown in Fig. 7b, and HOLD FOR
APPROXIMATELY 40 SECONDS.
9. Close cabinet lid and lower platforms to the ground.
If lift does not raise but the motor runs, check the
motor for proper direction of rotation and switch the
phases on the power supply line if necessary.
Fig. 6
FILL BREATHER CAP
Fill Reservoir
15