7
ENGLISH
1. General safety instructions
The ROCOOL 600 must be used only by expert personnel certified according to country-specific
standards.
Before first use, read this operating manual thoroughly to prevent improper use.
The ROCOOL 600 must be used only with the refrigerants indicated below. Other gases or fluids
must never be used with the ROCOOL 600.
Do not use or store the unit in environments that are not within the working temperature range.
Protect the ROCOOL 600 from rain or other external liquids.
Never exceed the manifold’s maximum pressure of 60 bar. This could irreparably damage the
sensors. There is also a danger of the sight glass breaking, which may injure the user.
During all work, make sure to wear personal protection gear that includes safety gloves and safety
glasses.
Avoid dropping the ROCOOL 600 from big heights
Do not overtighten the valves. This permanently reduces the valves‘ seal.
Connect only original Rothenberger accessories (external vacuum probe, Red Box) to the ROCOOL
600.
2. Technical data
Pressure display:
bar, psi, KPa, MPa
Temperature display:
°C, °F
Vacuum display:
microns, mbar, mmHg, Pa, mTorr
Power source:
9V battery, 550 MAh
Monitor (diagonal):
4 1/3“ / 11cm
Pressure measurement range:
-1 to 60 bar
Precision (at 22°C):
+/- 0.5% fs
Temperature measurement range:
-50°C – 200°C
Working temperature:
-10°C – 50°C
Connections:
4x ¼“ SAE (7/16“ UNF)
Max. recording time:
8h in device, 96h with Red Box
Coolants:
R11, R113, R114, R115, R116, R12, R1234yf, R123A, R124,
R125, R13, R134a, R141B, R142B, R143, R143A, R152A, R21, R218, R22, R227ea, R23, R290, R32,
R401A, R401B, R401C, R402A, R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B,
R407C, R407D, R408A, R409A, R410A, R410B, R411A, R411B, R412A, R413A, R414A, R414B,
R415A, R416A, R417A, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R427A,
R434A, R437A, R438A, R500, R502, R503, R504, R507A, R508A, R508B, R509A, R600, R600A,
R601, R601A, R718, R744 (subcritical).
3. ROCOOL 600 basic functions
1. Open the battery compartment and connect the 9V battery.
2. To turn on the ROCOOL 600, press the power button (1) for 3 seconds. When it starts up, RO
COOL 600 automatically calibrates the sensors to the current zero point.
3. To turn on the backlighting, press the backlight button (3) for 3 seconds. More current is
required when backlighting is on.
4. To change the settings on the ROCOOL 600, press the set button (4).
• Navigatethesettingsmenuwiththeupanddownarrowkeys(2), the set button (4) for confir-
mation, and the Delete key (7) to go to the previous step.
• Notpressinganykeyfor5secondsautomaticallytakesyoubacktotheoverviewscreen.
• Fromthesettingsmenu,youcanchangethefollowingparameters:
• Refrigerants
• Pressuredisplay
• Temperaturedisplay
• Intervalofrecording
• AmbienttemperaturedisplayorT2-T1
• T1/T2oroverheating/undercoolingdisplay

Table of Contents