Do you have a question about the Rowe WALLPHONO WP100 and is the answer not in the manual?
Unplug the device's power cord from the 110V outlet before proceeding with installation.
Set Mars Acceptor dip switches to positions 1-6 ON and 7-8 OFF for correct operation.
Attach blue self-stripping terminals to power cord wires, ensuring secure connection before reattaching jumper.
Secure the Detent bracket using #8-32 Hex Nuts to the mechanism partition, ensuring catch faces front.
Remove the front door's Bill Blockout and install the provided Bill Inlet.
Fasten the Mars Bracket Assembly to the Bill Acceptor using four #8 x 1/2 self-tapping screws.
Attach spacer, shoulder washer, and mount bracket using specified screws, allowing for initial adjustment.
Place the assembled Bill Acceptor onto the mounting bracket and check door fit, adjusting as needed.
Connect the fall stop cable to the pilot hole above the slug cup using a washer and wood screw.
Plug in the harness connector and route wires, connecting to the power jumper and control computer.
Enter service mode to set the coin switch value to 20 for 5-cent increments ($1.00 total).
| Power Handling | 100W |
|---|---|
| Sensitivity | 88 dB |
| Impedance | 8 Ohms |
| Enclosure Type | Bass Reflex |
| Frequency Response | 60 Hz - 20 kHz |
| Driver Size | 5.25 inches |
| Color | Black |