EasyManuals Logo

Rowenta DH4120 User Manual

Rowenta DH4120
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
EN
IN CASE OF PROBLEM
• Never dismantle your appliance. A poorly repaired appliance may pose risks to the user.
• Before contacting an approved Service Centre in our network, ensure that the appliance is in a
normal operating position and that the air inlet and outlet grills are completely unobstructed.
ENVIRONMENT PROTECTION FIRST!
Your appliance contains valuable materials which can be recovered or recycled
Models DH4110, DH4116, DH4120 also contain a fluorinated greenhouse gas as a coo-
ling agent (R134A) under the Kyoto Protocol, whose global warning capacity is 1300
times higher than carbon dioxide (CO2).
Model DH4130 also contains a fluorinated greenhouse gas as a cooling agent (R410A)
under the Kyoto Protocol, whose global warning capacity is 1975 times higher than car-
bon dioxide (CO2).
The fluorinated greenhouse gas contained in this appliance must not be released into
the atmosphere.
Leave it a local civic waste collection point.
Type of problem Points to check
The appliance does not work when
switched on.
- Water tank full.
- Positioning of the tank.
- Connection of the appliance.
The dehumidification capacity is too
low.
- That the filter is clean.
- The temperature is too low.
- Obstruction of the air inlet and outlet grills.
The desired level of comfort is not
reached after the appliance has been
operating for a long time.
- Doors and windows are closed.
- That the filter is clean.
- Source of steam in the room.
- Size of room too large.
The appliance is too noisy. - The appliance is placed on a flat and stable surface.
The appliance stops.
- Water tank full or not in place.
- Temperature too high or too low.
- Bad humidity setting.
The full indicator light is on.
- In case of first use, water tank not in place.
- Water tank is full.
The appliance freezes.
- Check filter is clean.
- Room temperature too low.
- Clear the air inlet and outlet grilles.
The air outlet vent does not open.
(Mod. DH4116, DH4120, DH4130)
- Vent blocked on opening
=> Switch off and restart appliance