Congratulations on your purchase of the Diamond
Detective.
IDENTIFICATION OF PARTS
1. Probe
2. Diamond Indicator
3. Ready Lamp
4. Wait/Low Battery Lamp
5. Battery Compartment
6. Conductive Panel
7. Small/Large Stone Switch
8. “ON” Button
9. “OFF” Button
*PRIOR TO TESTING, IT IS RECOMMENDED THAT THE TIP
OF THE PROBE BE CLEANED BY GENTLY WIPING ACROSS
A CLEAN SHEET OF PAPER *
OPERATIONAL CHECKOUT
1. Rotate the Thumbwheel (7) to the right for large
stones.
2. Press the “ON” button (8).
3. The Wait Lamp (4) will be lit.
4. All other display lamps will remain extinguished for
the wait period which is typically less than nine
seconds at room temperature. The time can increase
with low temperatures or a weak battery. After the
wait period there is a single beep.
5. If the waiting time exceeds twenty seconds or the Wait
Lamp fails to extinguish replace the battery.
6. The Diamond Tester is ready to use after the Wait
Lamp extinguishes and the Ready Lamp is lit.
7. When testing is completed always press the “OFF”
button. Always turn off the unit immediately after
testing to increase battery life.
AUTOMATIC ALARM
The Diamond Tester will sound alarm after 150 seconds
of inactivity. Whenever the “On” button is pressed the
timer resets to 150 seconds. If the unit alarm sounds
before you have completed your test simply press the on
button and continue your testing. Always press the
“OFF” button after testing to prolong battery life.
MAINTENANCE
Always place the protective cover over the probe
immediately after use. Probe tip damage is not
covered in the warranty.
The only maintenance required is: (1.) cleaning the
probe tip and (2) battery replacement.
SPECIFICATIONS
MODEL DIAMOND DETECTIVE
POWER SOURCE 9 VOLT BATTERY
NEDA SIZE 1604 (006P)
NET WEIGHT 105 GRAMS 3.7 OZ.
WARRANTY
Dymond Inc, provides that each Diamond Detective will be
free from defects in material and workmanship for a period
of two years from the date of purchase. (Batteries and
Probe Tip are not included in Warranty.) This warranty
becomes void by:
1. Unauthorized repair, misuse, modification, alteration,
tampering or breaking any factory seal.
2. Accidental damage, neglect or improper use.
Dymond Inc, shall not be held legally liable or responsible
for any error in display indication or the interpretation
thereof in the identification of any stones, minerals, gems or
gemstones by the Diamond Detective.
WARRANTY SERVICE
Should the Diamond Detective require warranty service
write or call Dymond Inc, for a return material
authorization (RMA). Be prepared to provide proof of
purchase. Pack the Diamond Detective securely along with
a description of the malfunction or problem and return unit
freight pre-paid to the address below. Include along with
the unit a copy of your dated purchase receipt. E.&O.E.
Dymond Inc.
3307 Industrial 25th Street
Fort Pierce, FL 34946
Phone (772) 429-0045 Fax (772) 429-0170
Question and Answer IconNeed help?

Do you have a question about the RS MIZAR Diamond Detective and is the answer not in the manual?

RS MIZAR Diamond Detective Specifications

General IconGeneral
BrandRS MIZAR
ModelDiamond Detective
CategoryTest Equipment
LanguageEnglish

Summary

Identification of Parts

Operational Checkout

Maintenance and Specifications

Warranty and Service Information

Interpreting the Indication

Metal Alert

Indicates probe tip in contact with user's hand or metal setting.

Diamond Simulants vs. Diamonds

Describes indications for simulants (no green lamp) and diamonds (flashing green lamp, beeping).

Preparation Prior to Testing a Stone

Diamond Testing Procedure

Stone Size Selection

Choose between LARGE or SMALL stone setting based on carat weight.

Testing Steps

Guides on holding the tester, stone, probe tip placement, and expected results.

Helpful Hints