1:1 Absolute Maximum Ratings
Supply Voltage : 12/24 Volt
Supply Current : 40 Amps per power bank
Standby Current : Typical : 55 milliamps (@13.8VDC, no peripherals attached)
Max : 65 milliamps (@13.8VDC, no peripherals attached)
Standby Temperature : -20 Deg C – 70 Deg C
Operating Temperature : -20 Deg C – 50 Deg C
1.2 Power
2 x 40Amp DC pins on pluggable connector
- These MUST be fused (fuse rating of 40Amps or less as the application requires).
1 x Ground / chassis connections
- If the siren output is going to be used, the ground chassis line should be rated to handle 15 Amps or more
The Primary Sense line is used to provide power to a single power output. This input should be protected with a fuse rated
at 1 Amp
1.3 Digital Inputs
12 x Positive Switched
12 x Negative Switched
1.4 Analog Inputs
Primary battery sense
1.5 Analog Monitoring
Bank A voltage sense
Bank B voltage sense
Internal temperature monitor
Output channel current monitors
Siren system current monitor
1.6 Outputs
16 x High side current and voltage protected outputs
12 X Positive switching Monitor Outputs
4 x Positive or Negative switching Monitor Outputs
100W siren speaker output
1.7 Communication
1 x RS485 Communication
1 x Optilink input.
2 x CAN Bus 2.0
RSG Engineering Limited Telephone : 01543 438800 Fax : 01543 438801 Email : sales@rsg-ontop.com Web : www.rsg-ontop.com
2:36
UNIVERSAL CONTROLLER PLUS (MCS-32) USER GUIDE V3 1 : SPECIFICATION
1 : Specification