rMPEDANCE SELECT
(REAR PANEL)
~
0'4
'N523'e
5.'V
VOLTAGES INDICATED BY TEST POINTS HAVE 2~ TO!..ERANCE.
TOP VALUE IS NO LOAD CONDITION. BOTTOM VALUE IS
FULL LOAD (1 AMP) CONDITION. VOLTAGES APPLY TO INPUT
VOLTAGES SHOWN.
5
0'5
'N523'B
5.'V
G FOR 1OOVAC OPERATION:
INSTALL W1.W2 AND WS.
USE TRANSFORMER (11SVX2.1SVX2.24VA) RTSlf23O1-OO27-OO.
FOR 117VAC OPERATION:
INSTALL W1.W2.W4 AND W6.
USE TRANSFORMER (11SVX2.28VX2.24VA) RTSII23O1-OO26-OO.
FOR 234VAC OPERATION:
INSTALL W3.W4 AND W6.
USE TRANSFORMER (11SVX2.28VX2.24VA) RTSlf23O1-OO26-OO.
~ THERMAL BREAKER 95 DEGREES CELS~US OPEN~NG TEMPERATURE
LOCATED BETWEEN T1 AND T2.
2. CAPACrTANCE VALUES SHOWN: MrCROFARADS/VOLTS.
,. ALL RESrSTORS ARE rN OHMS. ,/4- WATT. CARBON FrLM. +-5~.
NOTES: UNLESS OTHERWISE SPECIFIED Page 11
I CONTRACT No.1
IRTS
SYSTEMS Bu'.bank. Callfa'.nla
---
iD'.own
I R.NErLsoN
c:necked
SCHEMATrC DrAGRAM. TW POWER SUPPLY.
MODEL PS15
DWG NO
SIZE
J:ssued
NOT USED: 013
LAST USED: 017 .D2O.F"1.J1.P3.R27 .52. T2. TP7 .W7.U1.DS1
-..,-,1