Owners Manual
Niagara Rapid
Submersible Cover Pump
Multi-connection Adapter
Garden Hose Adapter
Carrying Handle
Easy Maintenance
1 Year Limited Warranty
Your Rx Clear® Niagara Rapids™ submersible pool cover pump is warranted against
defects in workmanship for a period of 1 year from date of purchase. Examine the
pump before usage or installation.
If the pump should fail for reason above and still within the warranty period it will be
repaired or replaced at the option of the manufacture discretion. All defective
product returned under this limited Warranty will be fully inspected to determine the
cause of failure before Warranty is approved. To file a claim contact the Authorized
Retailer the product was purchased from, you will be asked to provide a copy of your
sales order. Any / all freight charges incurred in returning the pump to the retailer will
be the sole responsibility of the purchaser
This limited Warranty is in lieu of all other warranties to the maximum extent
permitted by applicable law. The company disclaims all other warranties and
conditions, express or implied, including but not limited to the implied warranties of
merchantability and fitness for a particular purpose. Replacement of defective
products as provided under this Warranty is your exclusive remedy. The company will
not be liable in contract or tort for any direct, consequential, special or incidental loss
or damage arising out of the use, misuse or inability to use this product. This
Warranty is not transferable by the original owner to a subsequent owner of the pool
cover pump.
Some states do not allow the exclusion or limitation of incidental or consequential
damages so the above limitation or exclusion may not apply to you.
This Warranty gives you specific legal rights. You may have additional rights, which
vary from state to state.
Question and Answer IconNeed help?

Do you have a question about the Rx Clear Niagara Rapid and is the answer not in the manual?

Summary

1 Year Limited Warranty

Specifications

Product Description

Details the Rx Clear Niagara Rapids submersible pool cover pump's design and features.

Safety Guidelines

Provides essential safety warnings regarding electrical shock, cord handling, and pump operation.

General Safety Information

Operation Instructions

Operation Warnings

Highlights risks of electrical shock, handling wet components, and servicing procedures.

Troubleshooting Chart

Lists common pump symptoms, their causes, and recommended corrective actions.

Operating Information

Explains pump operation principles like shaft seal lubrication and thermal protection.

Getting Started

Step-by-step instructions for connecting the hose and starting the submersible pump.

Overview

The Rx Clear® Niagara Rapids™ Submersible Cover Pump is designed for residential swimming pools and sumps, offering a reliable solution for water removal. This pump is specifically engineered to handle water from pool covers and sumps, ensuring crystal clear water.

Function Description:

The primary function of the Rx Clear® Niagara Rapids™ pump is to remove unwanted water from residential swimming pools and sumps. It operates by submerging into the water and pumping it away through a connected discharge hose. The pump is equipped with an automatic reset thermal protector, which safeguards the motor by cutting off power if the temperature rises unduly. Once the motor cools sufficiently, the switch resets automatically, and the motor restarts. This feature prevents damage to the motor from overheating. The pump is designed to pump down to approximately ¼" (6mm) of water, but it should not be allowed to run without at least 5-½" of water to prevent damage to the shaft seal, which relies on water for lubrication. It is crucial not to use this pump for applications involving salt water or brine, as this will void the warranty. It is also not designed as a waterfall or fountain pump.

Important Technical Specifications:

  • Power Supply Required: 110V, 60HZ
  • Liquid Temperature Range: 32°F to 95°F (0°C - 35°C)
  • Discharge: 1-½" FNTP
  • Max. Delivery Capacity:
    • 250W model: 6000 l/h
    • 400W model: 7000 l/h
    • 500W model: 10,000 l/h
  • Max. Pressure:
    • 250W model: 0.6 bar
    • 400W model: 0.8 bar
    • 500W model: 0.85 bar
  • Max. Delivery Height:
    • 250W model: 6m
    • 400W model: 8m
    • 500W model: 8.5m
  • Max. Submersion Depth:
    • 250W model: 5m
    • 400W model: 7m
    • 500W model: 7m
  • Motor: Sealed for cooler running, bearings never need lubrication.
  • Power Cord: 3-prong grounding-type power cord.

Usage Features:

  • Multi-connection Adapter: Allows for versatile connection options for discharge hoses.
  • Garden Hose Adapter: Facilitates easy connection to standard garden hoses for water discharge.
  • Carrying Handle: Provides convenience for transporting the pump.
  • Grounding: The pump is supplied with a grounding conductor and a grounding-type attachment plug, ensuring electrical safety. It must be connected to a properly grounded receptacle. If a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle in accordance with state and local codes.
  • Placement: The pump should be placed on a desirable flat area for optimal operation.
  • Safety Precautions: Users should wear safety glasses, keep the work area clean and well-lit, and keep visitors at a safe distance. The pump should not be handled with wet hands or when standing on wet or damp surfaces. The power cord should not be buried or used to lift the pump.
  • Water Type: This pump is evaluated for use with water only and should not be used to pump corrosive liquids, as this could damage the enclosure and cause an electrical short.
  • Dry Running: Avoid running the pump dry, as this can damage the integrity of the enclosures and cause an electrical short.
  • Icy Conditions: Operation in icy conditions can cause unnecessary wear on the pump. If these conditions exist, cease operation and remove the pump from the pool cover.

Maintenance Features:

  • Easy Maintenance: The design allows for straightforward maintenance.
  • Periodic Inspection: Users should periodically inspect the product and system components, keeping them free of debris and foreign objects. Routine maintenance is required to ensure optimal performance.
  • Cord Care: Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Damaged or worn cords should be replaced or repaired immediately.
  • Impeller Cleaning: If the pump operates but delivers little or no water, or if it starts and stops too often, the impeller may be clogged. The pump should be removed, and the impeller cleaned.
  • Intake Screen Cleaning: A restricted intake screen can also lead to reduced water delivery. The intake screen should be cleaned regularly.
  • Troubleshooting: The manual includes a troubleshooting chart to help diagnose and resolve common issues such as the pump not starting, starting and stopping too often, or operating with little to no water delivery. This chart provides causes and corrective actions for various problems.
  • Pre-Service Disconnection: Always disconnect power before servicing the pump to prevent electric shock. Release all pressure within the system and drain all water before servicing any component.
  • Hose Inspection: Check hoses for weak or worn conditions before each use, ensuring all connections are secure.