M CALSS APPLICATION
11
when using M class applications, appropriate PPE must be worn (eg. P2, OEL value etc)
1
4
5
3
2
IMPORTANT!
TO MAINTAIN M CLASS APPLICATION, THE VACUUM CLEANER MUST BE USE D WITH THE PLATIC DISPOSAL
BAG.
1. Install the cartridge filter following the same procedure as the standard application.
2. Place Plastic disposable bag into the tank, ensure the flange fully fitted around the inlet.
3. Fold the top edge of the plastic disposable bag over the rim of the tank.
4. Place Paper disposable bag into the tank, ensure the flange fully fitted around the inlet.
5. Assemble the power head to the tank, and start the dry vacuum as per standard application.
10
Dust class Max permeation
level
Suitable for Material
• Wood dusts (beech, oak)
• Paint dust particles
• Ceramic dusts
• Dusts from plastics
• Dusts with MAC values
≥0.1mg/m
3
• Wood dusts up to 1200
W/50 I
< 0.1%
WARNING