15
Overload:
The overload indicator will light if the generator’s wattage/
amperage capacity is exceeded. To reset the generator,
remove all loads from the generator and press the reset
button (see fi g. 1). Add loads back to the generator one at
a time being careful not to exceed the generators wattage
rating.
Lubricant:
The oil indicator will light and the engine will automatically
shut off whenever the lubricant level in the engine becomes
low. The engine may not be restarted until suffi cient engine
lubricant has been added to the generator.
NOTE: It is normal for the indicator lights to illuminate and/
or blink each time the engine is started. Once the engine
warms up, the lights should default to the pattern above.
CHECKING/ADDING LUBRICANT
See Figure 3.
CAUTION:
Attempting to start the engine before it has been
properly filled with oil will result in equipment
failure.
Engine lubricant has a major influence on engine
performance and service life. For general, all-temperature
use, SAE 10W-30 is recommended. Always use a 4-stroke
motor lubricant that meets or exceeds the requirements for
API service classifi cation SJ.
NOTE: Non-detergent or 2-stroke engine lubricants will
damage the engine and should not be used.
Loosen the screws at the side of the engine cover.
Remove cover and set aside.
Unscrew the oil cap/dipstick and remove.
Wipe dipstick clean and re-seat in hole; do not
re-thread.
Remove dipstick again and check lubricant level.
Lubricant level should fall between the minimum and
maximum marks on the dipstick.
If level is low, add engine lubricant until the fluid level
rises between the minimum and maximum marks on
the dipstick.
Replace and secure the oil cap/dipstick.
USING FUEL STABILISER
Fuel gets old, oxidizes, and breaks down over time. Adding
a fuel stabilizer (not included) extends the usable life of fuel
and helps prevent deposits from forming that can clog the
fuel system. Follow fuel stabilizer manufacturer’s directions
for correct ratio of stabilizer to fuel.
Mix fuel stabilizer and gasoline prior to filling the tank
by using an approved fuel container and shaking
gently to combine.
NOTE: To control the amount of fuel stabilizer being
added to the engine, always mix fuel stabilizer with
gasoline before fueling the tank rather than adding
fuel stabilizer directly into the generator’s fuel tank.
Replace and secure the fuel tank cap.
Start and run the engine for at least 5 minutes to
allow stabilizer to treat the entire fuel system.
OXYGENATED FUELS
CAUTION:
Do no use E15 or E85 fuel (or fuel containing
greater than 10% ethanol) in this product. It is a
violation of federal law and will damage the unit
and void your warranty.
Fuel system damage or performance problems resulting
from the use of an oxygenated fuel containing more than
the percentage of oxygenates stated below are not covered
under warranty.
Ethanol. Gasoline containing up to 10% ethanol by volume
(commonly referred to as E10) is acceptable. E15 and
E85 are not.
CHECKING/ADDING FUEL
See Figure 4.
WARNING:
Gasoline and its vapours are highly flammable
and explosive. To prevent serious personal injury
and property damage, handle gasoline with
care. Keep away from ignition sources, handle
outdoors only, do not smoke while adding fuel,
and wipe up spills immediately.
When adding fuel to the generator, make sure the unit is
sitting on a fl at, level surface. If the engine is hot, let the
generator cool before adding fuel. Always fi ll the fuel tank
outdoors with the machine turned off.
Remove the fuel cap.
Fill the fuel tank to 25 mm below the top of the fuel
neck.
Replace and secure the fuel cap.
NOTE: Always use unleaded gasoline with a pump octane
rating of 91 or higher. Never use old, stale, or contaminated
unleaded fuel, and do not use an oil/fuel mixture. Do not
allow dirt or water into the fuel tank. Do not use E85 fuel.
STARTING THE ENGINE
See Figures 5-7.
CAUTION:
On a level surface with the engine off, check the
lubricant level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
To start generator the fi rst time:
Your new inverter generator is equipped with a mechanical
fuel pump. The initial start up will require additional pulls of
the recoil starter to prime the fuel system.