C
Christopher DavidsonJul 26, 2025
What to do if Ryobi RY08420 Blower engine will not start?
- JJeffrey MartinezJul 26, 2025
If the Ryobi Blower engine won't start, there could be several reasons: * **No spark:** Check for spark by removing the spark plug, reattaching the spark plug cap, and laying the spark plug on the metal cylinder. Pull the starter rope and watch for a spark at the spark plug tip. If there's no spark, try again with a new spark plug. * **No fuel:** Push the primer bulb until it's full of fuel. If the bulb doesn't fill, the primary fuel delivery system might be blocked, and you should contact a servicing dealer. * **Engine is flooded:** Let the unit sit for 30 minutes. Put the choke in the RUN position, hold the throttle at full, and pull to start. If it doesn't start after 15 pulls, replace the spark plug and try again.