1
1
2
2
3
3
4
4
5
5
6
6
D D
C C
B B
A A
Scale Sheet
Size FCSM No. DWG No. Rev
B
Note:
(1): DZ is recomended for automatic
door.
(2): FW V3.00.H and later
(*): "PP" only for magnetic switches
FIRST STOP
5CM
5CM
5CM
LAST STOP
MICROZED V3.5 BOARD
FIRST STOP
LAST STOP
5CM
15CM
5CM
5CM
20CM
PTC PTC
ab
+t
SDFS
UP
SDFS
DN
EOS
UP
EOS
DN
MONOSTABLE
MAGNETIC SWITCHES
NS
NS
PP(*)
(1)
PP (*)
DZ
MAGNETIC SWITCHES
SDFS
UP DN
SDFS EOS
UP
EOS
DN
BISTABLE
PP (*)
A350HYDV1W5_DOOR-INFO.Sch
5 of 16
INPUTS/DOOR INFO
AC Contactors
4 3
4 3
Rdn
Cp
SFTYINSP
ON=NORMAL
OFF=INSPECTION
(REVISION)
P
2 1
Cp
CONT
Rdn
RSV
RESERVE CAR
FULL
SWITCH
STOP FRMN
FIREMEN SWITCH
CAR
ONRDY
CAR STEP
FULL LOAD
EMERGENCY
INSP
UP DN
INSP
EN
S.&A.S. Ltd.
Jieh Chouf
Lebanon
support@sascontrollers.com
2 1
MICROZED V3.5 HYDRAULIC WIRING DIAG:
IP3
SWITCH
OVERWEIGHT
OR
FINAL LIMIT
SWITCH
R-Sfty
11 12
(2)
NS