EasyManua.ls Logo

Sabiana ENY-SP-180 User Manual

Sabiana ENY-SP-180
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Energy Smart
Recovery Units
controlled mechanical
ventilation system
TECHNICAL MANUAL
Product is subject to and complies
with Regulation EU 1253/14 - ERP2018
Question and Answer IconNeed help?

Do you have a question about the Sabiana ENY-SP-180 and is the answer not in the manual?

Sabiana ENY-SP-180 Specifications

General IconGeneral
BrandSabiana
ModelENY-SP-180
CategoryVentilation Hood
LanguageEnglish

Summary

Energy Smart Recovery Units Overview

Technical Manual Introduction

Provides a brief introduction to the technical manual for the Energy Smart units.

General Features of Energy Smart Units

High Efficiency Ventilation and Heat Recovery

Details the core functionality of units for efficient air exchange and heat recovery.

Automatic Airflow Control System

Explains the Pro version's automatic airflow control using humidity and CO2 sensors.

Product Range Overview

Vertical Unit Models (ENY-SP, ENY-S)

Lists and describes vertical ENY-SP and ENY-S unit models and their specifications.

Horizontal/Vertical Unit Models (ENY-SHP)

Lists and describes horizontal/vertical ENY-SHP models and their specifications.

Fast Unit Selection Guide

Pro ENY-SP Vertical Selection Data

Provides performance curves and data for selecting Pro ENY-SP vertical units.

Standard ENY-S Vertical Selection Data

Provides performance curves and data for selecting Standard ENY-S vertical units.

ENY-SHP Version Selection Data

Provides performance curves and data for selecting ENY-SHP units.

Vertical Unit Dimensions and Weight

Pro ENY-SP Dimensions and Weight

Detailed physical dimensions and weight specifications for Pro ENY-SP models.

Standard ENY-S Dimensions and Weight

Detailed physical dimensions and weight specifications for Standard ENY-S models.

Vertical Unit Installation Methods

Wall Mounting Instructions

Guidance on securely mounting vertical units on walls using provided brackets.

Floor Mounting Instructions

Guidance on installing vertical units on the floor using optional feet.

Vertical Unit Model Specifications

Pro ENY-SP Model Features

Details on Pro ENY-SP models, including advanced airflow control.

Standard ENY-S Model Features

Details on Standard ENY-S models, including timing profile control.

Vertical Unit Component Construction

ENY-SP and ENY-S Main Components

Description of the main construction features and materials for ENY-SP and ENY-S units.

Vertical Unit Operating Modes

Flow Configuration Options

Explains standard and optional inverted flow configurations for vertical units.

Vertical Unit Thermal Performance

ENY-SP Performance Curves

Detailed fan performance curves for ENY-SP models (Supply/Extract Air, SFP).

ENY-S Performance Curves

Detailed fan performance curves for ENY-S models (Supply/Extract Air, SFP).

Horizontal Unit Dimensions and Weight

ENY-SHP-150 Dimensions and Weight

Physical dimensions and weight for the ENY-SHP-150 model.

ENY-SHP-170 Dimensions and Weight

Physical dimensions and weight for the ENY-SHP-170 model.

ENY-SHP-270 Dimensions and Weight

Physical dimensions and weight for the ENY-SHP-270 model.

Horizontal Unit Model Specifications

Pro ENY-SHP-150 Airflow Control Features

Details on ENY-SHP-150 with advanced airflow control.

Pro ENY-SHP-170 Construction Features

Description of main components for Pro ENY-SHP-170.

Pro ENY-SHP-270 Construction Features

Description of main components for Pro ENY-SHP-270.

Horizontal Unit Operating Modes

ENY-SHP-150 Installation and Flow Modes

Explains installation and airflow modes for ENY-SHP-150 units.

ENY-SHP-170 Configuration Modes

Details airflow configurations and modes for ENY-SHP-170 units.

ENY-SHP-270 Configuration Modes

Details airflow configurations and modes for ENY-SHP-270 units.

Horizontal Unit Efficiency Curves

ENY-SHP Thermal Performance Curves

Graphical representation of thermal efficiency for ENY-SHP models.

ENY-SHP Fan Power Absorption Curves

Graphical representation of fan power absorption for ENY-SHP models.

Unit Selection Procedure

Key Selection Procedure Steps

Step-by-step guide for selecting the appropriate unit model.

Unit Selection Example

Practical example illustrating the unit selection process.

Operating Point and Power Checks

Final checks for operating points and power consumption during selection.

Free-Cooling and Free-Heating Management

Bypass Damper Operation Modes

Explanation of bypass damper modes for free-cooling and free-heating.

Control Panel Interface

T-EP Control Menus and Functions

Details on the T-EP control panel's user settings and technical menus.

Centralised Control System

Air Quality Monitoring Strategy

Explains the centralized control strategy using humidity and CO2 sensors.

Electric Heater Versions

Electric Heater Power Specifications

Details power ratings for units equipped with electric heaters.

Unit Accessories - Heating and Mounting

Electric Duct Pre-heaters

Information on circular electric external duct pre-heaters.

Installation Feet

Details on adjustable feet for unit installation and lifting.

Unit Accessories - Control Systems

Automatic Flow Rate Control Sensor

Description of the pressure sensor for automatic flow rate control.

Unit Accessories - Smart Connectivity

Humidity Sensor and KNX Interface

Details on capacitive humidity sensor and KNX interface kit.

Regulatory Compliance

EU 1253/14 Compliance Verification

Verification items and declarations of conformity with EU Regulation 1253/14.

EU 1254/14 Annex IV Data Tables

Detailed compliance tables according to EU Regulation 1254/14 Annex IV.

CE Declaration of Conformity (ENY-SHP-150)

EU Declaration for ENY-SHP-150 Model

Official EU Declaration of Conformity for the ENY-SHP-150 unit.

CE Declaration of Conformity (H/V Models)

EU Declaration for Horizontal/Vertical Models

Official EU Declaration of Conformity for H/V unit models.

CE Declaration of Conformity (ENY-SHP-270)

EU Declaration for ENY-SHP-270 Model

Official EU Declaration of Conformity for the ENY-SHP-270 unit.

CE Declaration of Conformity (Vertical Units)

EU Declaration for Vertical Unit Models

Official EU Declaration of Conformity for various vertical unit models.

Passivhaus Certification Overview

ENY-SP-280 Certification Criteria

Main criteria met for ENY-SP-280 Passivhaus certification.

Passivhaus Certification Criteria

Comfort and Efficiency Criteria

Details on comfort and efficiency criteria for certification.

Passivhaus Certification Data

Leakage, Acoustics, and Filter Data

Additional certification data including leakage, acoustics, and filters.

Passivhaus Certification - Frost Protection

Heat Exchanger and Coil Frost Protection

Measures for protecting heat exchangers and coils from frost.