2431 Galpin Court, Suite 140, Chanhassen, MN 55317
1-800-993-2114
Tools Required:
Diculty Level: Intermediate
(1) 3/4” Wrenches or Sockets
(2) 9/16” Wrenches or Sockets
Cordless Drill (optional)
Phillips Screw Driver
Screen Kit (Optional):
11/32” Wrench or Socket
The HydroSweep® Pro ACD (Aquatic Current Device) is designed to help preserve your waterfront and control algae,
trash, and decaying debris on the surface of the water, while maintaining naturally occurring aquatic life. For optimal
results, the HydroSweep® Pro ACD should be positioned twelve inches (12”) o the oor of your waterfront and
positioned level (see page 4). Setting the pump too close to the bottom of the body of water may have an adverse impact
on the shoreline and aquatic life, which may be illegal in some jurisdictions including Minnesota. You should check with
your local ordinances regarding any limitations on use. Upon start-up of the HydroSweep® Pro ACD, the water may
initially appear dirty since debris, silt, and sediment are being moved from the bottom of the body of water. This should
settle in time.
THERE IS A SERIOUS RISK OF ELECTRIC SHOCK IF THE
HydroSweep® Pro ACD IS NOT PROPERLY ASSEMBLED, HANDLED
OR INSTALLED. WE RECOMMEND THAT YOU USE A LICENSED
ELECTRICIAN. THE UNIT MUST BE CONNECTED TO A GFCI (15 OR
20 AMP) CIRCUIT.
PLEASE READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY
(SEE ADDITIONAL PRODUCT WARNINGS ON THE LAST PAGE)
Inspect the HydroSweep® Pro ACD for damage immediately upon
delivery. IF THE PRODUCT IS DAMAGED, STOP: DO NOT USE A
DAMAGED PRODUCT. Report any damage to your dealer.
Installation and Operating Instructions
Technical Support: 1-800-993-2114 ext. 1

Other manuals for SafeShore HydroSweep Pro

Question and Answer IconNeed help?

Do you have a question about the SafeShore HydroSweep Pro and is the answer not in the manual?

SafeShore HydroSweep Pro Specifications

General IconGeneral
BrandSafeShore
ModelHydroSweep Pro
CategoryOutboard Motor
LanguageEnglish

Summary

Installation and Operating Instructions

Safety and Handling Precautions

Important warnings regarding electric shock, proper assembly, handling, and inspection for damage.

Tools and Preparation

Lists required tools and indicates an intermediate difficulty level for installation.

Product Purpose and Placement Guidelines

Explains the HydroSweep Pro ACD's function and recommended initial positioning off the water floor.

Assembly Procedure

Attaching Shaft and Installing Bracket

Step-by-step instructions for attaching the shaft to the bail and installing the shaft support bracket and rotator.

Securing Components and Final Positioning

Instructions for securing the shaft cap, installing the dock mount, and setting the final 12-inch positioning.

Keypad Operation

Understanding Keypad Functions

Details the HydroSweep Pro keypad buttons, modes (Counter Clockwise, Eco Mode, Clockwise), and status lights.

Programming the Unit

Provides a step-by-step guide for programming the HydroSweep Pro ACD's operational settings.

Limited Warranty

Critical Safety Warnings

Electrical Shock and Grounding Hazards

Emphasizes risks of electric shock, proper grounding, GFCI circuits, and consulting electricians.

Operational Safety Precautions

Includes warnings about keeping clear of the pump, pinch points, element exposure, freezing, and misuse.