SAFT AMERICA INC.
COMPONENT MAINTENANCE MANUAL
4579
24-31-05
PAGE 118
Jan 30/98
FAULT POSSIBLE CAUSE REMEDY
Cell with swollen case Cell operated with low
electrolyte level,
deterioration of separator
and damaged plates
Replace with new SAFT cell
(DISASSEMBLY, ASSEMBLY)
Cell with zero voltage when
battery circuit is open
Short circuited cell Replace with new Saft cell
(DISASSEMBLY, ASSEMBLY)
Low insulation resistance Leakage of electrolyte Disassemble and clean battery
(DISASSEMBLY AND
CLEANING)
Check electrolyte level (TESTING
and FAULT ISOLATION)
Fault Isolation
Figure 106 (Page 5 of 5)

Table of Contents