EasyManua.ls Logo

SainSmart 2M542 - Setting; Current Set; Reduce Current Function

SainSmart 2M542
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Setting
By switching the following DIP-SWITCH, user can change the output current and
micro-steps of driver.
8
7
6
5
4
3
2
1
D
I
P
O
N
↓
O
N
O
F
F
• Current Set
SW 1 SW 2 SW 3 Current (A
rms
)
ON ON ON 1.00 A
OFF ON ON
1.46 A
ON OFF ON 1.91 A
OFF OFF ON
2.37 A
ON ON OFF 2.84 A
OFF ON OFF 3.31 A
ON OFF OFF 3.76 A
OFF OFF OFF 4.20 A
• Reduce Current Function
SW 4 Function
ON Maintain full current in the stop state
OFF Automatically reduce current in the stop state