Page 9 of 15
2.4 Temperature setting
Push button or to change Setting temperature from 18-30°C
2.5
Dim
Push button or by holding for 3 seconds to reduce the intense of LED light. When turn off air
conditioner,
the intense of light will change to be normal
2.6
Remote Handset
Can
use function in remote control as usual such as SLEEP, TIMER
3.
SYSEM FEATURES
3.1 Watchdog : In controlling system, when system error according to computerized system which may come
from
unstable of electrical voltage or from noise, system will set computer to reset immediately.
3.2 Compr
essor delay protection : In case of compressor stop operation, it always delay time before restart
again
for 3 minute. And in case of electric shut off from system and resupply again, it will delay operating of
com
pressor for 3-4 minute by randomly.
3.3
Compressor minimum on time : compressor always have to operate at least 24 seconds before stop
operation.
3.4 Au
to restart : In case of electric shut down, when electricity restart as normally, system will operate
according
to last setting program except SLEEP and TIMER that will be cancelled by value will keep record
in
MEMORY after changing in value at least 5 seconds. So if the changing in value does not reach 5
seconds before electric shutdown, when system restart, it will operate according to memory value before
ch
anging.
3.5 Fre
eze protection : In Cool or Dry mode, if T
indoor coil
≤ 0°C and compressor has been operating at least 10
minutes
continuously. Freeze will occur. System will stop compressor operation and fan speed will operate
in
low.
System
will return to operate as normally when T
indoor coil
≥ 7°C or turn off product.
3.6 De
frost function : In Heat mode, if T
outdoor coil
has low value compressor will operate as in effective way.
Defrost
function will help to protect compressor from damaging.