Installation guide
XS4 Reader
European view
22
95,5
95,5
2a
2b
2a
2b
83,5
q
27
95,5
q
"E" "S"
WRDx0E4x
WRDx0S4x
WRDx0E4xK
WRDx0s4xK series
Template
Plantilla
Schablone
Gabarit de perçage
Sjabloon
Mall
60
60
60
60
52
52
R
6
60
60
95,5
95,5
15,5
83,5
q
20,5
E
Card reader installation guide
Guía de instalación lector de tarjetas
Kartenleser installationsanleitung
Guide d'installation lecteur de cartes
Kaartlezer Installatiehandleiding
Kortläsare installationsguide
Eng
D
F
NL
SVE
Installation Instalación Installation Installation Installatie Installation
Eng
E
D
F
NL
SVE
1
2 3
Real size
Real size
1/4
PZ1 (X4)
TORX 10 (X2)
3M SCOTCHLOK BUTT CONNECTOR UY2 (X4)
TM
TM
(X4)
Gang electrical standard box
dulo caja eléctrica estándard
Standard schalterdose
Plots d'encastrament standard
Standaard elektrische inbouwdoos
Standard apparatlada
Eng
E
D
F
NL
SVE
Eng
E
D
F
NL
SVE
Question and Answer IconNeed help?

Do you have a question about the Salto WRD 0E4 Series and is the answer not in the manual?

Overview

This document describes the SALTO XS4 Reader, an access control device designed for various installation scenarios. The manual provides detailed information on its physical characteristics, electrical specifications, installation procedures, and compliance statements.

Function Description

The SALTO XS4 Reader is a card reader for access control systems. It is designed to read RFID cards and communicate with a control unit (e.g., SALTO CU42xx) to grant or deny access. Some models also include a keypad for PIN entry, offering an additional layer of security. The device features visual and audible signaling to indicate various statuses such as card acceptance, rejection, privacy mode, and standard opening/locking. It supports both standard and office-mode operations.

Important Technical Specifications

The XS4 Reader operates within a temperature range of -35°C to +66°C (-31°F to +150°F) for most models (WRDOB, WRDOS, WRDOBK, WRDOSK) and -25°C to +66°C (-13°F to +150°F) for others (WRDOJ, WRDOGK, WRDOJK). Humidity tolerance is between 35% and 85%.

RF Characteristics:

  • RFID Frequency: 13.56 MHz. Output max power is +25 dBm for all models listed (WRDOB, WRDOJ, WRDOS, WRDOBK, WRDOJK, WRDOBF, WRDOJF, WRMOB, WRMOJ, WRDPOB, WRDPOJ, WRDMOB, WRDMOJ).
  • Bluetooth Smart Frequency: 2.4 - 2.445 - 2.483 GHz. Output max power is +8 dBm for most models, with WRDOS having +2.8 dBm.

Power Consumption (Note 1):

  • Reader only: 150 mA
  • Reader + Keypad: 250 mA
  • Note 1: Installer must account for this data to dimension the CU42xx power supply.
  • Note 2: Not to be used with Scotchlok butt connector UY2. SALTO recommends using one cable per wall reader.

Cable Type and Max. Distances:

  • UTP Cat5e 2 pairs (AWG24): 100m (328ft) for reader, 60m (196ft) for reader+keypad.
  • UTP Cat5e 4 pairs (AWG24 + SP224861/SP224895): 250m (820ft) for reader, 150m (492ft) for reader+keypad.
  • Twisted pairs (AWG18 Note 2): 400m (1312ft) for reader, 280m (918ft) for reader+keypad.

Software:

  • Control: 0151, 0152, 0153 (depending on model).
  • Bluetooth Module: 0136.

Physical Dimensions: The standard XS4 Reader measures approximately 95.5mm (3-3/4") in width and 141mm (5-9/16") in height. The depth varies, with the main body being around 29.5mm (1-5/32") and the mounting plate adding another 23mm (29/32"). The device is designed for surface mounting and can be installed with a standard electrical box (gang electrical standard box).

Usage Features

The XS4 Reader offers clear visual and audible feedback for various operations:

  • Card Rejection: Red light (1 sec) with a high-pitched buzzer (1 sec).
  • Privacy or Emergency Status: Red light flashing 5 times (50/50x3+off300) with a high-pitched buzzer flashing 5 times (50/50x3+off300) for 3 seconds.
  • Standard Opening: Green light (1 sec) with a low-pitched buzzer (0.3 sec).
  • Standard Locking: Red light (0.5 sec) with a low-pitched buzzer (0.2 sec).
  • Open Plus Office Mode: Green light (400/200 ms) with a high-pitched/low-pitched buzzer (400/200 ms) for 2.4 seconds.
  • CLR Button: Orange light (continuous) with a high-pitched buzzer (continuous).
  • Reset: Orange light (50/100 ms) with a low-pitched buzzer (50/100 ms) for 450 ms.

The device is designed for integration with SALTO CU42xx control units. It supports various cable connections, including 3M™ Scotchlok™ butt connectors (UY2) for certain wiring configurations, although SALTO recommends using one cable per wall reader. The installation process involves mounting the reader, connecting it to the control unit, and securing it with screws.

Maintenance Features

  • Cleaning: The electronic device should be cleaned with a damp cloth and mild soapy water. Abrasive soaps or sprays should never be used. For best performance, stainless steel components should be cleaned regularly.
  • Troubleshooting: The manual provides guidance on FCC compliance, including steps to correct interference such as reorienting the receiving antenna, increasing separation between equipment and receiver, connecting to a different circuit, or consulting a technician.
  • Installation: The device is designed for easy installation with clear diagrams illustrating the mounting process and cable connections. It is crucial to follow the instructions to ensure correct operation and avoid damage.
  • Pre-programmed Locks: If a door is closed without the lock having been programmed, it will automatically lock and can only be opened with a Portable Programming Device (PPD). For any questions or doubts, users should contact their authorized SALTO supplier.

Electrical Warnings:

  • A minimum distance of 20 cm must be maintained between the device and the human body.

Mechanical Warnings:

  • The device should be used with a lock suitable for the door's mass, frequency of use, and fire rating.
  • Handle the product with care during installation to avoid aggressive contact that could damage the unit.
  • Avoid contact with oil, paints, or acids.
  • Do not paint the door with the mortise lock or electronic device already mounted.