CORRENTE MASSIMA
AUT. 16.5 A
CORRENTE MASSIMA
MAN. 16.5 A
SERVE AD IMPOSTARE LA
CORRENTE MASSIMA DI
SOVRACCARICO DEL MOTORE
RITARDO CORRENTE
4 s
RITARDO CORRENTE
4 s
SERVE AD IMPOSTARE IL RITARDO
DELL’INTERVENTO PER LA
PROTEZIONE SULLA CORRENTE
RANGE 0.5 ÷ 90.0A (SA607.xx)
RANGE 1 ÷ 8s
AUT. INDICA CHE IL VALORE DELLA
CORRENTE MASSIMA SI È IMPOSTATO
CON L’AUTOAPPRENDIMENTO
MAN. INDICA CHE IL VALORE
DELLA CORRENTE MASSIMA
È STATO IMPOSTATO
MANUALMENTE
RANGE 0.5 ÷ 18.0A (SA604.xx)
CORRENTE MINIMA
AUT. 9.9 A
CORRENTE MINIMA
AUT. 9.9 A
RANGE 0.5 ÷ 87.0A (SA607.xx)
RANGE 0.5 ÷ 15.0A (SA604.xx)
SERVE AD IMPOSTARE LA
CORRENTE MINIMA
DEL MOTORE
CORRENTE MINIMA
OFF
PULSANTE MANUALE
INSTABILE
PULSANTE MANUALE
INSTABILE
INSTABILE AVVIA IL MOTORE
SOLO DURANTE LA PRESSIONE
SUL PULSANTE MAN
PULSANTE MANUALE
STABILE
STABILE AVVIA IL MOTORE CON UN
IMPULSO SUL PULSANTE MAN;
ARRESTA IL MOTORE CON UN
IMPULSO SUL PULSANTE RESET
5. PROGRAMMAZIONE
OFF. ESCLUDE IL
CONTROLLO SULLA
CORRENTE MINIMA
10
5.2 Programmazione avanzata
ATTESA PRESENZA
RETE OFF
OFF ESCLUDE L’ATTESA
PRESENZA RETE
ATTESA PRESENZA
RETE OFF
ATTESA PRESENZA
RETE 1 min
SERVE AD IMPOSTARE
L’ATTESA PRESENZA RETE
RANGE 1 ÷ 30min
SQUILIBRIO FASI
10 %
SQUILIBRIO FASI
OFF
SQUILIBRIO FASI
10 %
SERVE AD IMPOSTARE
LO SQUILIBRIO DI CORRENTE
SULLE FASI
RANGE: OFF - 5% - 10% - 15%
OFF ESCLUDE LO
SQUILIBRIO FASI
AUT. INDICA CHE IL VALORE DELLA
CORRENTE MINIMA SI È IMPOSTATO
CON L’AUTOAPPRENDIMENTO