EasyManua.ls Logo

Samsung AC018BNADCH - Page 10

Samsung AC018BNADCH
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Installation Procedure
English
Installation Procedure
Connecting wire conduits
When connecting cables between the indoor unit and the
outdoor unit, use conduits to protect the cables.
1 Drill holes on the conduit plate in accordance with
their use and quantity.
AC018BXADCH
Drill conduit holes on the side cabinet. (knock
out holes)
Conduit Holes
AC024/030/036/042/048BXADCH
Use a nipper to remove conduit holes from the
lower part of the cabinet.
(Do not remove it by hammering.)
Conduit Holes
2 Insert the cables through the conduits, and then fix the
conduits to the conduit plate with the lock nuts.
3 Apply silicone to the end of the hose to prevent rain
from entering the hose.
Silicone
Conduit inserted into the outdoor unit
4 Connect the cables to the outdoor units.
For how to connect the cables, refer to the next page.
5 Attach the conduit plate to the product.
Air conditioning system examples
When using earth leakage circuit breaker (ELCB) for a
single phase
Communication cable
Indoor Unit
Main power
cable
MCCB
1
Outdoor-to-indoor power cable
Outdoor Unit
Earthing
ELB
ELCB
1
OR
The appearance of the unit may be different from the
picture depending on the model.
CAUTION
If the outdoor unit is installed in a location vulnerable
to an electric leak or submergence, make sure to
install an ELCB.
AC018BXADCH, AC024BXADCH: ELCB must be installed
since this product is equipped with a base heater.
DB68-11274A-00_IM_CAC Universal Outdoor_AA_EN.indd 10DB68-11274A-00_IM_CAC Universal Outdoor_AA_EN.indd 10 2021-09-14 오전 9:21:572021-09-14 오전 9:21:57