EasyManua.ls Logo

Samsung AC018MXSCCC/AA - User Manual

Samsung AC018MXSCCC/AA
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
đͱʒʪࡠAđĘUA²ࢥ࣍ÃʒͱͱθƸϩ࣎
AđǹƊAAAࢥ࣍ĮЇϩʒͱͱθƸϩ࣎
SINGLE RAC for America
(Low Ambient, R410A,
Cooling Only System)
SINGLE
Technical
Data Book

Other manuals for Samsung AC018MXSCCC/AA

Questions and Answers

  • W
    Willie BakerSep 12, 2025
    What to do if my Samsung AC018MXSCCC/AA Air Conditioner shows error on DC-Link voltage sensor?
    • K
      Kristi MayerSep 12, 2025
      If your Samsung Air Conditioner shows an error on the DC-Link voltage sensor (Short or Open), contact an Authorized Service Center.
  • E
    Erika Powell DVMAug 25, 2025
    Why is my Samsung AC018MXSCCC/AA Air Conditioner heating operation restricted?
    • Y
      Yvonne BrownAug 25, 2025
      If the heating operation of your Samsung Air Conditioner is restricted at an outdoor temperature over Theat_high value (default: 30 °C), adjust the outdoor temperature settings.
  • C
    christophermartinAug 25, 2025
    What to do if my Samsung AC018MXSCCC/AA Air Conditioner has a gas leak?
    • V
      vsnyderAug 26, 2025
      If your Samsung Air Conditioner has a gas leak, contact an Authorized Service Center for assistance.
  • D
    Debra MontgomerySep 23, 2025
    What to do if my Samsung AC018MXSCCC/AA Air Conditioner has error due to mismatching capacity of indoor and outdoor unit?
    • H
      hamiltonrubenSep 23, 2025
      If there's an error due to mismatching capacity of the indoor and outdoor units of your Samsung Air Conditioner, ensure that the capacities of the indoor and outdoor units match.
  • C
    Caroline BowmanSep 13, 2025
    What to do if my Samsung AC018MXSCCC/AA Air Conditioner shows error on EVA IN sensor of indoor unit?
    • R
      rodriguezbrandonSep 13, 2025
      If your Samsung Air Conditioner shows an error on the EVA IN sensor of the indoor unit (Short or Open), contact an Authorized Service Center.
  • J
    Janice CarterSep 18, 2025
    What to do if my Samsung AC018MXSCCC/AA Air Conditioner shows error on IPM Heat Sink sensor of inverter 1?
    • K
      Kenneth DuranSep 18, 2025
      If your Samsung Air Conditioner shows an error on the IPM Heat Sink sensor of inverter 1 (Short or Open), contact an Authorized Service Center.
  • M
    Matthew SerranoSep 6, 2025
    What to do if my Samsung AC018MXSCCC/AA has H/W DC_Link Over Voltage Error?
    • E
      Elizabeth ZavalaSep 6, 2025
      If your Samsung Air Conditioner displays a H/W DC_Link Over Voltage Error, contact an Authorized Service Center.
  • E
    ehernandezSep 7, 2025
    What to do if my Samsung Air Conditioner shows error due to operation failure of inverter compressor?
    • D
      danieloconnorSep 7, 2025
      If your Samsung Air Conditioner shows an error due to the operation failure of the inverter compressor, contact an Authorized Service Center.
  • T
    Trevor GonzalezSep 23, 2025
    What to do if my Samsung AC018MXSCCC/AA Air Conditioner shows AC Input Voltage Sensor Error?
    • D
      Donald LeonardSep 23, 2025
      If your Samsung Air Conditioner shows an AC Input Voltage Sensor Error, contact an Authorized Service Center.
  • J
    joseph29Aug 30, 2025
    What to do if my Samsung Air Conditioner shows error due to abnormal rotation of the compressor?
    • J
      jbutlerAug 31, 2025
      If your Samsung Air Conditioner shows an error due to abnormal rotation or unconnected wire of the compressor, contact an Authorized Service Center.

Summary

Product Specifications

Indoor Unit Technical Specifications

Detailed technical specifications for indoor units including power, efficiency, and dimensions.

Outdoor Unit Technical Specifications

Detailed technical specifications for outdoor units including power, efficiency, and dimensions.

Capacity Tables

Cooling Capacity Tables by Model

Shows cooling capacity (Total, Sensible) based on indoor and outdoor temperatures.

Capacity Correction

Cooling Capacity Correction Factors

Provides correction factors for cooling capacity based on pipe length and level difference.

Electrical Wiring Diagrams - Indoor Unit

Electrical Wiring Diagrams - Outdoor Unit

Sound Data - Indoor Unit

Indoor Unit Sound Pressure Level and NC Curves

Provides sound pressure levels and NC curves for indoor units.

Sound Data - Outdoor Unit

Outdoor Unit Sound Pressure Level and NC Curves

Provides sound pressure levels and NC curves for outdoor units.

Operation Range

Cooling and Drying Operating Conditions

Specifies the outdoor/indoor temperature and humidity limits for operation.

Piping Diagrams

Piping Diagram for AC018 Models

Illustrates refrigerant and internal piping for AC018 indoor/outdoor units.

Piping Diagram for AC024;030;036 Models

Illustrates refrigerant and internal piping for AC024/030/036 models.

Indoor Unit Installation

Indoor Unit Installation Location Requirements

Details criteria for choosing an indoor unit installation location.

Indoor Unit Drilling and Mounting

Guides on drilling holes and mounting the installation plate for indoor units.

Connecting Indoor Unit Cables

Instructions for connecting power and communication cables to the indoor unit.

Outdoor Unit Installation

Adding Refrigerant and Procedures

Guides on adding refrigerant (R-410A) and related procedures.

Samsung AC018MXSCCC/AA Specifications

General IconGeneral
TypeSplit System
Energy Efficiency Ratio (EER)11.5
RefrigerantR410A
Compressor TypeInverter
Cooling Capacity18, 000 BTU/h
Heating Capacity18000 BTU/h
Power Supply60Hz, 1-Phase
Outdoor Unit Noise Level49 dB(A)
Voltage208/230 V

Related product manuals