01 PREPARATION
English-7
- Install the outdoor unit in a place (such as near buildings etc.) where it can be prevented from sea breeze which can
damage the outdoor unit.
Outdoor unit
Outdoor unit
Sea breeze Sea breeze
Sea
Sea
- If you cannot avoid installing the outdoor unit by the seashore, construct a protection wall around to block the sea
breeze.
Protection wall should be constructed with a
solid material such as concrete to block the sea
breeze and the height and the width of the wall
should be 1.5 times larger than the size of the
outdoor unit. Also, secure over 27.6 inch between
the protection wall and the outdoor unit for
exhausted air to ventilate.
Protection wall
Outdoor unit
Sea breeze
Sea
- Install the outdoor unit in a place where water can drain smoothly.
t If you cannot nd a place satisfying above conditions, please contact manufacturer. Make sure to clean the sea water
and the dust on the outdoor unit heat exchanger and spread corrosion inhibitor on heat exchanger. (At least one
time per one year.)
t You have just purchased a system air conditioner and it has been installed by your installation specialist.
t This device must be installed according to the national electrical rules.
t With an outdoor unit having net weight upper than 132.2 lb, we suggest do not install it suspended on wall, but
considering oor standing one.
t When the outdoor unit is installed near seashore or in a place where sulfuric acid gas may leak, corrosion may
occur in outdoor unit and cause product malfunction.