EasyManua.ls Logo

Samsung AC052HBLDKH - Main Part Inspection Method

Samsung AC052HBLDKH
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-36 Samsung Electronics
4-8 Main Part Inspection Method
Compare terminal Resistance Remark
Red, Blue 185Ω ± 10% Main
Blue, White 183Ω ± 10% Sub
Part Breakdown Inspection Method
Indoor Unit Temperature Sensor
Measure sensor resistance with a multimeter
Normal At the normal temperature 37kΩ~8.3kΩ(-7˚C~+30˚C)
Abnormal
,0Ω...Open or Short
Indoor Unit BLDC FAN Motor
Measure terminal resistance with a multimeter
Normal At the normal temperature(10˚C~30˚C)
Abnormal
,0Ω...Open or Short
Outdoor Unit
Outdoor Temperature Sensor
&
Cond Temperature Sensor
Measure sensor resistance with a multimeter
Normal At the normal temperature 37kΩ~8.3kΩ(-7˚C~+30˚C) see 12-2-6 and 12-2-8
Abnormal
,0Ω...Open or Short
Outdoor Unit
Discharge Temperature Sensor
Measure sensor resistance with a multimeter
Normal At the normal temperature 563kΩ~157kΩ(0˚C~+30˚C) see 12-2-7
Abnormal
,0Ω...Open or Short
Outdoor Unit BLDC FAN MOTOR
Measure terminal resistance with a multimeter
Normal At the normal temperature(10˚C~30˚C)
Abnormal 0Ω...Open or Short
Outdoor Unit 4way Valve Solenoid
Measure resistance with a multimeter
Normal At the normal temperature(10˚C~30˚C) 1.6KΩ±15%
Abnormal
,0Ω...Open or Short
wire pin number Resistance Remark
RED - BLACK 1-3 over 1M +300V motor power
WHITE - BLACK 4-3 1K ~ 2K +15V control power
YELLOW - BLACK 5-3 200K ~ 300K control
BLUE - BLACK 6-3 10K ~ 50K pulse
wire
pin number Resistance Remark
RED - BLACK 1-3 over 1M
+300V motor power
WHITE - BLACK 4-3 1K
~ 2K
+15V control power
YELLOW - BLACK 5-3 200K
~ 300K
control
BLUE - BLACK 6-3 10K
~ 50K
pulse
ORANGE - BLACK 7-3 10K
~ 50K
reverse
Remark : 4-5-4~7 contents are for heat pump model (DH18/24BT) .

Other manuals for Samsung AC052HBLDKH

Related product manuals