Troubleshooting
Samsung Electronics 4-39
*1.PWFS0WFS$VSSFOUFSSPS&SSPS$PEF&(cont.)
Yes
Turn off the power and change the location of
the temperature sensor or replace it.
No
Are the position and measuring value of the
temperature sensor normal?
Continue
Check the connection status of compressor.
No
Is compressor wire connected properly to the
compressor?
Yes
1. Replace the compressor : If the resistance
value between phases of the compressor is
different.
ĺ Power on.ĺ Check the normal operation.
ĺ End the service.
2. Reassemble wire
: If the wire connection of
the compressor is wrong.
ĺ Power on. ĺ Check the normal operation.
ĺ End the service.
3. Replace the compressor : When loud
abnormal n
oise generates (metal cutting or
grinding noise), or severe vibration.
No
Check the compressor.
1. Are all the resistance values
between phases matched?
(U ļ V, U ļ W, V ļ W)
2. Is compressor wiring normal? (disconnection,
wrong connection)
3. Is there any abnormal noise
from
compressor rotation?
Yes
Replace the compressor.
No
Yes
Is there a reading of MegaΩ of resistance
between compressor body and chassis?
Open the valve.
No
Is service valve fully opened?
Continue