Installation Procedure
Type
Model Outdoor unit Input current (Amperes) Power supply
Indoor unit Outdoor unit
Rated
Voltage range
Outdoor unit
Indoor
unit
Total MCA MFA
Hz Volts Min
.
Max
.
Cooling Heating
B
AC052MN4DKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC052NN4DKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC052MNNDKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC052NNNDKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC052MNMDKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 2.5 22.5 22.5 25.0
AC052MNLDKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.7 21.7 21.7 25.0
AC052MNCDKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC052MNJDKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC052MNADKH/EU
AC052MXADKH/EU
50 220 to 240 198 264 20 20 1.6 21.6 21.6 25.0
AC060MNNDKH/EU
AC060MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC060NNNDKH/EU
AC060MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC060MNMDKH/EU
AC060MXADKH/EU
50 220 to 240 198 264 20 20 2.5 22.5 22.5 25.0
C
AC071MN4DKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC071NN4DKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC071MN4PKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.5 21.5 21.5 25.0
AC071MNNDKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC071NNNDKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC071MNMDKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 2.5 22.5 22.5 25.0
AC071MNLDKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.7 21.7 21.7 25.0
AC071MNCDKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.0 21.0 21.0 25.0
AC071MNADKH/EU
AC071MXADKH/EU
50 220 to 240 198 264 20 20 1.6 21.6 21.6 25.0
AC071MNMSEH/EU
AC071MXASEH/EU
50 220 to 240 198 264 20 20 3.5 23.5 23.5 25.0
D
AC100MNMSEH/EU
AC100MXASEH/EU
50 220 to 240 198 264 22 22 3.5 25.5 25.5 28.0
NOTE
1 Voltage range
• Units are suitable for use on electrical systems
where voltage supplied to unit terminal is not
below or above listed range limits
2 Maximum allowable voltage variation between
phases is 2%.
3 Wire size & type must comply with the applicable
local and national code.
• Wire size: Based on the value of MCA.
• Wire type: 60245 IEC57(IEC) or H05RN-
F(CENELEC) grade or more.
4 MFA is used to select the circuit breaker and the
ground fault circuit interrupter (earth leakage circuit
breaker).
5 MCA represents maximum input current.
• MFA represents capacity which may accept MCA
• Abbreviations
MCA: Min. Circuit Amps. (A)
MFA: Max. Fuse Amps. (A)