38
Testing operations
7. DIP switch option
ON
1 2 3 4
ON
1 2 3 4
SW507
SW508
DIP switch(SW507) option
On (default) O
Switch 1 Auto address Manual address
Switch 2 Disable snow prevention control Enable snow prevention control
Switch 3
Silence Mode option
Switch 4
When snow prevention mode is in use, eco mode(standby mode)will not be functional.
When DPM installation is applied, the time for auto addressing will take 1~2minutes.
During the addressing,
and will be repeatedly displayed in order for 2 indoor unit connection, , and
for 3 indoor unit connection, , , and for 4 indoor unit connection.
When addressing is completed,
, , , and will be repeatedly displayed in order for 2 indoor unit
connection,
, , , , and for 3 indoor unit connection, , , , , ,
and for 4 indoor unit connection.
DIP switch(SW508) option
On(default) O
Switch 1 Auto Silence Mode Manual Silence Mode
Switch 2 - -
Switch 3 - -
Switch 4 - -
8. Silence Mode DIP switch option
(ACHCAPKH, ACHCAPNH, ACHCADKH, ACHCADNH, ACJXADEH, ACJXADGH,
AC100JXADEH1)
DIP switch(SW507) option
Switch 3 Switch 4 Operation
On On Disable Silence mode
On O Silence mode 1st step
O On Silence mode 2nd step
O O Silence mode 3rd step
CAC GD-EU_IM_32793A-23_EN.indd 38 2016-05-25 오후 7:08:49