Brand | Samsung |
---|---|
Model | AC100RN4DKG |
Category | Air Conditioner |
Language | English |
Safety instructions for handling electrical components, power cords, and grounding.
Detailed steps for disassembling various indoor unit models.
Disassembly steps for AC026RN1DKG and AC035RN1DKG indoor units.
Disassembly steps for 4-way cassette indoor units including AC052/071/100/120/140RN4DKG models.
Disassembly steps for 4-way cassette indoor units including AC071/100/120/140RN4PKG models.
Disassembly steps for AC100/120/140RNCDKG indoor units.
Disassembly steps for AC052RNCDKG and AC071RNCDKG indoor units.
Disassembly steps for AC026/035/052/071RNADKG and AC100RNTDKG indoor units.
Disassembly steps for AC026RNLDKG and AC035RNLDKG indoor units.
Disassembly steps for AC052RNLDKG and AC071RNLDKG indoor units.
Disassembly steps for AC100/120/140RNMDKG indoor units.
Disassembly steps for AC026/035/052/071RNNDKG indoor units.
Disassembly steps for AC026/035/052RNJDKG indoor units.
Detailed steps for disassembling various outdoor unit models.
Disassembly steps for AC026RXADKG and AC035RXADKG outdoor units.
Disassembly steps for AC052RXADKG outdoor units.
Disassembly steps for AC071RXADKG outdoor units.
Disassembly steps for AC140RXAD*G outdoor units.
Procedures for setting indoor unit address and installation options using the remote controller.
Checks to perform before diagnosing issues, including test run and view modes.
Troubleshooting guide for outdoor unit errors, listing error codes, meanings, and remarks.
Diagnostic steps for indoor temperature sensor open or short circuit failures.
Diagnostic steps for indoor heat exchanger temperature sensor open or short circuit failures.
Troubleshooting steps for indoor unit fan errors, including checks for motor and PCB.
Troubleshooting steps for communication errors between indoor and outdoor units after tracking.
Diagnostic steps for indoor unit float sensor errors, focusing on water levels and pump operation.
Troubleshooting steps for EEPROM circuit failures, including assembly and soldering checks.
Troubleshooting steps for E407 error related to high pressure switch or connector.
Diagnostic steps for outdoor units not receiving power, specifically for 3-phase products.
Diagnostic steps for outdoor units not receiving power, specifically for 1-phase products.
Troubleshooting for indoor/outdoor communication errors (1 min.) identified by Error Code E202.
Troubleshooting for communication errors between outdoor unit INV and MAIN MICOM (1 min.) with Error Code E203.
Troubleshooting for outdoor sensor errors, including temperature and OLP sensors.
Troubleshooting for reverse or loss of phase detection in 3-phase outdoor units.
Troubleshooting steps for compressor down issues caused by freezing control.
Troubleshooting steps for outdoor unit fan errors, including connection and voltage checks.
Troubleshooting for compressor starting or rotation errors, checking wires and resistance.
Troubleshooting for full current or PFC over-current errors, checking installation and valve status.
Troubleshooting steps for IPM over current errors, checking installation and wiring.
Troubleshooting for DC LINK voltage errors and AC input voltage sensor errors.