Samsung Electronics 5
2-1-1 Key features of the EHS(SPLIT)
Integrated Heating & Cooling system
Plate Heat exchanger is a integral part in heating & cooling system. For user’s convenience, PHE is integrated into the system.
This concept will help space saving and lower costs for pipe line reduction.
Running Costs-Reduction of Up to 33.5%
Samsung EHS, known for its world class efficiency (12kW floor heating system with 4.63), can reduce 33.5% of your running costs
as compared to a gas boiler.
High Performance at Low Temperature
Samsung EHS is made up of an inverter compressor optimally operated according to the outdoor temperature, offering heating
performance of 90% at -10°C and reliable frost protection at -25°C.
Heat pump operating range of DHW : -25 ~ 35 °C
At the temperature -25 °C ~ -20 °C, operation is available but capacity cannot be guaranteed.
2-
1-2
Key features of the MONO HT
Hot water temperature (Max. LWT 70°C )
T
he R-32 refrigerant heatpump system has implemented a maximum discharge water temperature of 70°C even
at low ambient temperature.
Extended Heat pump operating rage (-30°C ~ 43°C)
T
he low-temperature operation range has been extended to -30 °C to enhance the reliability of low-temperature
heating.
High heating performance
I
t guarantees 100% performance even at -25°C.
* Based on a leaving water temperature of 55°C. Not available on the 12kW and 14kW single-phase models.
Low noise ( 35dB(A) @3m )
By improving major parts, noise level has been greatly reduced compared to the conventional.
Using a 4-Step Quite Mode, keep it as low as 35dB(A)*