EasyManua.ls Logo

Samsung AQ09MSBX - Alignment and Adjustments

Samsung AQ09MSBX
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics 3-1
3. Alignment and Adjustments
3-1 Test Mode
Q How to Approach Test Mode
You can approach the Test Mode by pressing the on/off switch of
indoor unit for 5 seconds.
Q Test Mode Operation Option
After installing the air conditioner, check whether each subordinate is normally operated or not by operating the Test Mode.
Temperature Display Part : Display the set option at one-second intervals. (Only for models having the temperature display part)
ex) 0b0000-1730F8 : 0b
00
00
17
30
F8
0b ...(Repeat)
When an error occurs, display the Error Mode.
LED Display
Cause Follow-up Measures
Waiting Operation
LAMP
OPERATION TIMER TURBO
Indoor temperature
sensor error
(OPEN / SHORT)
Check assembling status of the sensor part’s
connector on the indoor unit main PCB
• Measure the resistance value on both sides –
connector no. 1 and no. 2 (E1), no. 3 and no. 4
(E2) – by separating the sensor part’s connector
Indoor heat exchanger
temperature sensor error
(OPEN / SHORT)
Indoor fan motor speed
detecting error
(Occur when it continues
for 15 seconds at below
450rpm)
• Check assembling status of the Motor Hall IC
output connector (CN44) on the indoor unit
main PCB
EEPROM error
(Option memory)
* Display only for models
having the returning
function for the power fail-
ure
• Reset options
• Replace the PCB
Blink all lamps
When there is an option
related error
When options are not set
When there is an option
data error
• Reset options
* If not meet the above DATA, replace sensors.
Temp.
(°C)
Resistance
Value(KΩ)
Temp.
(°C)
Resistance
Value(KΩ)
Others
15 14.68 30 8.31
20 12.09 35 6.94
25 10.00 40 5.83
The error of
DATA is
±2%.